Hunter AC solenoids and valves.
Valve Wire Sizing (Maximum One-Way Distance in Feet Between Controller and Valve)
Ground
Wire Size
Control Wire (ft)
18 AWG /
1.0 mm
16 AWG /
1.2 mm
14 AWG /
1.6 mm
12 AWG /
2.0 mm
10 AWG /
2.5 mm
8 AWG / 3
mm
6 AWG / 4
mm
18 AWG / 1.0
mm
850
1040
1210
1350
1460
1540
1590
16 AWG / 1.2
mm
1040
1340
1650
1920
2150
2330
2440
14 AWG / 1.6
mm
1210
1650
2150
2630
3080
3450
3700
12 AWG / 2.0
mm
1350
1920
2630
3390
4170
4880
5400
10 AWG / 2.5
mm
1460
2150
3080
4170
5400
6670
7690
8 AWG / 3
mm
1540
2330
3450
4880
6670
8700
10530
6 AWG / 4
mm
1590
2440
3700
5400
7690
10530
13330
Pump Start Relay Wiring and
Online Setup
In this article, we will discuss the following topics:
Summary
Operation Chart
Wiring (24 VAC)
Wiring to Power Source
Online Setup
Pump Start Relay Operation per Zone
Summary
Copyright 2020 Hunter Industries. All Rights Reserved.
45
Содержание Hydrawise HCC
Страница 1: ......
Страница 29: ...Step 4 Copyright 2020 Hunter Industries All Rights Reserved 29 ...