So we have a flow that has gone through the meter of 8,224.7 Litres. To calculate this into
Gallons is easy 8,224.7 / 3.78 = 2175.84 gallons.
Flow Meter - Testing Meter
If your flow meter is working but is not recording data in your
Dashboard
or events, follow
the steps here:
1. Make sure sensor is configured
[21]
in the software.
2. Make sure controller is online. If not, please use link
[22]
for Wi-Fi troubleshooting steps.
3. Remove the wire splices at the flow meter connection in the field. Tap the two wires
together that run to the controller 10 times, as each contact will record a pulse.
Refresh the app to see if the flow usage was registered.
4. If app registered flow usage, your wiring and system are set up correctly. Reconnect to
the flow meter and run a large flow (lots of sprinklers) zone. Did you get a flow on your
app? If
YES
, all is OK. If
NO
, contact [email protected]
[23]
.
5. If app did not register flow usage, test the sensor inputs on the controller. You can use
the same method with a paper clip or wire to make contact between sensor 1 or 2 and
the common terminal. Do this 10 times and then check for flow data usage at the home
screen. If
YES,
there is a problem with the wire running to the flow meter. If
NO
,
contact [email protected]
[23]
.