JINHHC05 RevF 27/04/12
HERALD
COMPACT 5
CleanBurn Stove
Installation and Operating Instructions
Страница 1: ...JINHHC05 RevF 27 04 12 HERALD COMPACT 5 CleanBurn Stove Installation and Operating Instructions ...
Страница 2: ...ng This stove has been designed and assembled so that it may be used to burn wood logs in a Smoke Control Area Find out if you are in a Smoke Control Area by contacting your Local Authority The Herald Compact 5 has been fitted with a permanent stop that prevents closure of the secondary air slider Removal of this will lead to the appliance potentially causing smoke emissions Without the permanent ...
Страница 3: ...ing control body in advance of any work starting CO Alarms Building regulations require that whenever a new or replacement fixed solid fuel or wood biomass appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s i...
Страница 4: ...for long periods without first adjusting the controls to a safe setting Careful air supply control should be exercised at all times Fume Emission WARNING NOTE Properly installed operated and maintained this appliance will not emit fumes into the dwelling Occasional fumes from de ashing and refuelling may occur However persistent fume emission is potentially dangerous and must not be tolerated If f...
Страница 5: ...liance If the alarm sounds unexpectedly follow the instructions given under Warning Note in the Fume Emission section In the Event of a Chimney Fire Raise the alarm Call the Fire Brigade Close appliance air controls Move furniture ornaments etc away Place a fireguard in front of stove Check the chimney breast for signs of excessive heat Ensure the Fire Brigade can gain access to your roof space in...
Страница 6: ...ate until Place a flue outlet gasket in position on the top plate of the stove and lower the flue collar or blanking plate as required on to the stove top taking care to line up the studs with the fixing Secure in place using the M6 nuts and washers Slide the remaining gasket on to the studs of the flue collar or blanking plate and secure in place on the back plate Unless the optional flue damper ...
Страница 7: ...side of the Baffle clears the Baffle Support lower the Baffle into the Fire Box and remove Slide the base of the Side Brick towards the centre of the stove and remove Pull the top edge of the Rear Brick forward and Lift the Baffle and slide to the left When the right side of the Baffle clears the Baffle Support lower the Baffle into the Fire Box and remove To assemble the stove simply reverse the ...
Страница 8: ...tallation If you have any doubts about the suitability of your chimney consult your local dealer stockist Connection to the Chimney The chimney must be swept before connection to the stove An existing fireplace opening can be bricked up or sealed with a register plate A short length of flue pipe of minimum 125mm internal diameter may then be used to connect the stove to the chimney This flue pipe ...
Страница 9: ...150mm or more is left around the sides of the stove to obtain maximum heat output and to gain access to the rear of the stove The hearth should extend at least 225 mm from the front of the stove If the stove is to stand in an appliance recess it should stand wholly above a solid non combustible hearth at least 125 mm thick this may include the thickness of a solid floor If the stove is not to stan...
Страница 10: ... output for at least 24 hours On completion of the installation and commissioning ensure that the operating instructions and operating tools for the stove are left with the customer Advise the customer on the correct use of the appliance with the fuels likely to be used on the stove and warn them to use only the recommended fuels for the stove Advise the user on what to do should smoke or fumes be...
Страница 11: ...ed by moving the slider to the right On the double door versions the amount of air is increased by moving the sliders outwards This provides a conventional air draught to the bed of the fire Secondary Air Secondary air is controlled via the slider above the door it is this Airwash that keeps a clean and uninterrupted view of the fire The amount of air can be increased by moving the slider to the r...
Страница 12: ...new fuel charge will ignite quickly If there are too few embers add some kindling to prevent excessive smoke LIGHTING THE STOVE We recommend that you have two or three small fires before you operate your stove to its maximum heat output This is to allow the paint to cure in steadily and to give a long service life of the paint finish During this curing in process you may notice an unpleasant smell...
Страница 13: ...smoke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in...
Страница 14: ...paint and this can be cleaned with a soft brush Do not clean whilst the stove is hot The finish can be renovated with Hunter Stoves paint Glass Panel Clean the glass panel when cool with Hunter Stoves glass cleaner Highly abrasive substances should be avoided as these can scratch the glass and make subsequent cleaning more difficult Wet logs on heated glass a badly aimed poker or heavy slamming of...
Страница 15: ...the air controls fully open If the appliance has been unused for a long period of time such as during the spring and summer months a competent person should check the chimney for potential obstructions before lighting the stove Gaskets All gasket used on this appliance are produced from a heat resistant material called Manniglas The glass gasket will have to be replaced when a new piece of glass i...
Страница 16: ...spares Door Glass HH04 057 Glass Gasket HH04 058 Door Handle HCR06 059 Door Slider CH05 009 Slider Knob HHR08 045 Single Door HH04 055 Door Cover HH04 056 Glass Clip HHR08 046 Glass Clip Screw FSJM05008SS Rope Sealing Kit SCPH4SDSK Door Catch Assembly DCH4 ...
Страница 17: ...sembly DCH4 Door Slider HH04 091 Door Slider HH04 091 Slider Knob HHR08 045 Slider Knob HHR08 045 Right Hand Door HH04 069 Left Hand Door HH04 070 Glass Clip HHR08 046 Glass Clip HHR08 046 Glass Clip Screw FSJM05008SS Glass Clip Screw FSJM05008SS Rope Sealing Kit SCPH4NDSK Rope Sealing Kit SCPH4NDSK Left Hand Door Cross HH04 071B Right Hand Door Cross HH04 071A ...
Страница 18: ...ck HHC05 009 Riddling Bar Upper HHW05 034 Riddling Bar Lower HHW05 033 Catch Bar Single Door HH04 126 Double Door HH04 074 Operating Tool HFR07 040 Ash Pan HHC05 006 Cam Bar HH04 015 Riddling Support HH04 022 Rear Brick HH04 109 Tertiary Air Bar HH04 105 Recouping Baffle HHC05 007 Flue Gasket CH05 042 ...