SAFETY FEATURES ___________________________________________________________________________
HAND-OPERATED EMERGENCY
STOP
BUTTONS:
Emergency Stop buttons are located on each side of the cabinets for easy access. Once pressed, they
immediately cease the laminator’s operation and raise the rollers. Use these only in the case of an emergency
or you may damage an image during a process.
NOTE:
Once pressed, these buttons lock and must be turned clockwise to reset. Press the laminator main
power button to restart the operation. The laminator defaults to Program 1 upon restart.
FOOT-OPERATED EMERGENCY TAP SWITCHES:
Located on both sides of the laminator, pressing on these tap switches will immediately cease the laminator’s
operation and raise the rollers. Press the main power button to restart the operation.
COVERED FOOT SWITCHES:
One on each side of the laminator allow for complete user control when initially feeding an image into the nip or
for feeding a delicate image through the rollers. The cover prevents accidentally stepping on the foot switch and
starting the laminator.
þ
WARNING! The foot switch overrides the photo eyes. When the photo eye is blocked the laminator runs
in slow mode at a speed of 2.0 feet (0.6M) per minute. A BUZZER sounds and a light on the left cabinet
flashes if an operator blocks a photo eye warning of proximity to the nip. Use care to keep hands clear
of the rollers while using the foot switch to prevent possible injury.
PHOTO ELECTRIC
SAFETY
EYES:
A light beam path set directly in front and back of the laminating roller openings prevents foreign objects from
passing between the rollers. (The eyes are set for use at the factory and checked by the service representative.)
LOCKING CABINETS:
The cabinets that house the inner workings of the laminator include locks that maintenance or safety personnel
can open only with the supplied keys.
þ
WARNING! Use of the inside of the cabinets for storage may cause possible personal injury and/or
damage to the inner workings and will void the warranty.
DOOR INTERLOCK
Located on the left side cabinet (facing front of laminator), it automatically shuts the laminator off when the door
is opened.
þ
WARNING! For any servicing, ALWAYS turn the laminator and the main power circuit breaker off before
opening the side cabinets.
Содержание Image 6100
Страница 7: ...7 3 H IMAGE 6100 ULTRA FEATURES DIAGRAM _______________________________________________________ ...
Страница 36: ...36 3 H NOTES ______________________________________________________________________________________ ...
Страница 48: ...48 3 H ELECTRICAL DIAGRAMS ______________________________________________________________________ ...
Страница 49: ...49 3 H ELECTRICAL DIAGRAMS ______________________________________________________________________ ...
Страница 50: ...50 3 H ELECTRICAL DIAGRAMS ______________________________________________________________________ ...