020-9905 User Manual Q3 (Advanced 3 year old child) Rev G Page 23 of 82
© 2016 Humanetics Innovative Solutions
Figure 10.
Q3 Head Assembly including instrumentation
Head instrumentation – both accelerometer bracket arrangements
020-1013 (standard) and 020-1014 (optional ARS version) shown
Assembly and Disassembly
Disassembly
The head is attached to the neck though the load cell or the structural replacement. To
disassemble the head, first detach the load cell from the neck.
1.
First remove the head rear assembly by unscrewing the four button head cap
screws at the back of the head.
2.
The accelerometer array can be removed in order to reach the screws in the upper
neck load cell (or the load cell replacement).
3.
With the accelerometer array removed, the M5 SHCS screws that attach the load
cell to the neck can be reached through the top of the head.
4.
Remove the head and upper neck load cell or structural replacement from the neck.
5.
Turn the head upside down, and remove the FHCS screws at the base of the head.
Assembly
The head can be assembled to the dummy by reversing the order of the disassembly.