background image

REMOVING THE BACKREST ACTUATOR

1.  Power off the chair and unplug it.

2.  Using a Phillips-head screwdriver, remove the two screws from the safety sensor plate  
 

on the back of the chair (Fig.1).

3.  Pull the safety sensor cover backward to expose the zipper that connects the safety 
 

sensor cover to the chair (Fig.2).

4.  Using a paper clip, open the zipper, then remove the safety sensor cover (Fig.2).
5.  Carefully lift the safety sensor cover away from the chair (Fig.3).

Tools Required:

 Phillips-head screwdriver, wire cutter or any other instrument suitable for 

cutting zip ties, paper clip.

NOTE:

 SAVE ALL REMOVED PARTS FOR USE DURING REASSEMBLY

REPLACING THE MAIN PCB

April 04, 2012

It is imperative that Human Touch

®

 products are repaired in a manner that ensures product safety and regulatory compliance and that is fully consistent with the practices used 

during the manufacturing process. Therefore, Human Touch requires that all product repairs are performed using only factory-new parts and in accordance with these repair 
instructions. Failure to adhere to these instructions voids the product warranty and releases Human Touch from all liability for injury or product damage resulting from the repair.

SERVICE LEVEL: 3

(Fig.1)

(Fig.2)

(Fig.3)

AcuTouch

®

 6.0

Safety sensor 

cover

Safety sensor 

cover

Safety sensor 

cover

Zipper

1

Main PCB

Отзывы: