5

* There will be sparks flying during operating, keep distance between working field 

and vicinity.   

* Operating should be within duty-cycle. Over load will cause accelerated components 

aging and decreased use life, even machine damage. 

* Do not modulate or move the machine during operation. 

* Welders have strong electromagnetism and frequency interference, so keep away people with heart 

pacemaker or the articles which can be interfered by electromagnetism and frequency. 

* Do not squeeze or smite the welding cable. 

* Do not allow irrelevant people go to welding operation field. 

2.4. Safe Measures to be taken to assure the correct Installation and Position 

* Precaution must be taken to keep the operator and the machine from the foreign materials falling 

from up above.   

* The machine must be installed in the place where it can not be exposed to sun and rain. Also it 

must be stored in less humid place with the temperature range at 

10~40°C. 

* The machine should be placed at horizontal position, in case of turnover or shift.   

* There should be 50cm space about for the welding machine to have good ventilation.   

* Make sure that there is no metal-like foreign body to enter the welding machine 

* Make sure that there is no interference with the surrounding area at the installation site.   

* Take measures to prevent wind while operating in the strong wind since the welder is gas shielded.   

2.5 Safety Check 

Each item listed below must be carefully checked before operation:   

* Make sure that the welding machine has reliable earth connection.   

* Make sure input/output cable in good condition and no exposure. 

Regular check needs to be conducted by the qualified personnel after the welder has been installed 

over a period of six months, which involves as follows: 

        * Routine cleaning needs to be done to make sure that there is no abnormal loose parts happening in 

the welding machine. 

* The parts installed on the panel must guarantee that the welder works properly.   

* Check the welding cable to see if it can continue to be used before it is worn out.   

 

Notice: Cut off the power supply before opening the case to check. 

Please do not hesitate to contact us for technical assistance whenever you come across the problems 

you can not work out or you may deem difficult to fix.   

 

3.  Technical Specification

 

3.1 Environment to Which the Product is Subject 

* The surrounding temperature range:  when working: -5

~ +

40

                         

During transport or in storage: 

25

~ +

55

℃ 。

 

* Relative humidity:    when at 40

50%, 

when at 20

90%. 

*The height above the sea: below 1000m 
* Keep from raining when it is used outdoor. 

Содержание EDGE 190L

Страница 1: ...EDGE 190L Gasoline Welding Generator USER S MANUALS ...

Страница 2: ...erator s self protection 2 3 Operator s notice 2 4 Safe Measures to be taken to assure the correct Installation and Position 2 5 Safety Check 3 Technical Specification 3 1 Environment to Which the Product is Subject 3 2 Welding Generator s Principle 3 3 Main Technical Data 3 4 Standard applied 3 5 Remark Sign of Illustration 4 Control Panel 4 1 Control panel parts name and function 4 2 Control Pan...

Страница 3: ...neering and also could be applied to enterprise and public institution EDGE 190 Gasoline welding generator function features 1 Power output 120 240V 50Hz 2 0KW 2 Welding current 65A 190A 3 Electrode diameter 1 6 4mm 4 Welding current is adjustable by knob 2 Safety Operation 2 1 Safety Notice Electric shock may cause death Wear dry labor protection appliance Don t touch work piece or to ground line...

Страница 4: ...lammable materials at least 11 meters Prevent sparks to cracks or shady place Fire extinguisher should be allocated at working area No welding sealed vessel Acid liquor in battery may cause textile to corrode Wear exposure suit and rubber gloves Keep vertical shifting of battery avoid any slant Hot parts may scald people No touching on just finished welding parts No touching on just finished weldi...

Страница 5: ... body without insulation No welding vessel with flammable and explosive materials or sealed vessel No operating at very humid filed Prevent flying sparks from hurting people No touching on any position of engine or load by hands no matter they are wet or not Exhaust gas from welding and generating is harmful to health Keep good ventilation Welding arc light is harmful to health keep eyes away from...

Страница 6: ...ing machine Make sure that there is no interference with the surrounding area at the installation site Take measures to prevent wind while operating in the strong wind since the welder is gas shielded 2 5 Safety Check Each item listed below must be carefully checked before operation Make sure that the welding machine has reliable earth connection Make sure input output cable in good condition and ...

Страница 7: ...rrent range A 65 190 Duty cycle 50 Excitation type Self excitation and constant voltage Starting type Manual Work type 8 hours continuous working Gasoline generator Model LC188F Type Single cylinder fan cooled four stroke Output volume CC 389 Tank Dia X Journey mm 88 64 Rated rotated speed rpm 3000 Fuel Unleaded gasoline for vehicle Fuel capacity L 1 1L Rated power 13HP Tank capacity 30 5L Structu...

Страница 8: ... Illustration 4 Control Panel 4 1 Control panel parts name and function Item Name Qty Function 1 Start handle 1 Start engine refer to engine manual 2 Engine power switch 1 Start engine refer to engine manual 3 Fuel tank cap dipstick 2 Fuel charging and fuel quantity measurement 4 Welding current modulate knob 1 Adjust welding current 5 Toggle switch 1 Turn ON OFF the engine U0 X I2 U2 ...

Страница 9: ...oaded in the place where less dust 5 1 2 Avoid direct sunlight and place the machine at shady and cool area 5 1 3 Place the machine at flat field in case of any shift 5 2 Indoor operation 5 2 1 Operation should be at well ventilated place and exhaust waste gas to outside Keep away from air inlet and keep good ventilation during work 5 2 2 There should be at least 1 5m space between any obstacle an...

Страница 10: ...hether the parts are loose Check and make sure not loosen of bolts nuts and all the fasteners especially air and acoustic filter There should be no circuit broken short and loose 6 7 Check whether there are foreign objects inside or outside of the machine 6 7 1 Check whether there are tools or waste left inside and get rid of them 6 7 2 Check whether there are waste and flammable bodies around aco...

Страница 11: ... work 10 2 Choose correct welding cable and connect the power supply Connecting lug and terminal must be reliable in case of poor contact burning Cable diameter should match the standard 5 7A mm2 current flow 10 3 Keep good ventilation do not put other things on the machine so as to avoid any negative influence to heat elimination 10 4 Choose correct welding electrode according to work piece thick...

Страница 12: ...Regular check is important to gasoline engine function and lifetime Check items and agenda as below check and clean Replace Table 3 Note means check should be carried by technician or with special tool please contact distributor For 1st it should be the initial checking and process regular checking hereafter Machine Check and maintenance items Daily check 50 250 500 1000 Engine Check engine oil vo...

Страница 13: ...ine the fuse If it breaks off please replace a new one Check and replace the cylinder type winding Under low temperature The machine cannot start Fuel frozen Use winter oil Some frozen water in oil system Heating Discharge the water in the fuel tank fuel filter and inner of fuel pipeline inner Poor air discharge in oil pipe Let out the air The machine auto stop and the running speed can not reach ...

Страница 14: ... value Low rotate speed Adjust accelerograph to rated speed Generator cable burning Repair Low rotate speed Increase the rotate speed The length of cable between generater and loading is too long or the section of cable is too small Adjust fix position toshorten the distance and oversticking the cable dia Voltage drops when loading Main winding and the winding are burned Replace motor Overload Red...

Страница 15: ... 14 Main circuit chart Refer to drawing 3 15 Complete Set Specification Table 6 Item Description Quantity 1 EDGE190L gasoline welding generator 1set 2 Manual 1pc 3 Engine manual 1pc 4 Warranty Card 1pc 5 Spark plug sleeve spanner 1pc 16 Transport Storage The machines should be free from rain and snow during transportation and storage The warehouse should keep dry ventilation and free from corrosiv...

Страница 16: ...welder repaired at our expense within 12 months upon the purchase of welder if and when the welder is found either damaged partially or working improperly Explosive view 2 21 20 19 12 11 10 9 8 7 6 5 18 17 16 15 14 13 4 3 2 1 ...

Страница 17: ...16 Drawing 3 Main circuit chart ...