www.hugo-mueller.de
BA HUpro GB -22989- 2014-07-V03 - ED - A3 Seite 2
GB
Additional instruction master clock
Site 2 / 2
Button function
Symbol legend
1. Automatic-Mode: To access the enter-mode
2. Enter-Mode: To revert to the beginning of the current (sub-)menu.
Power plug symbol (flashing): While the power supply is disconnected, the display shows a power plug symbol. The
time switch is then operated in the battery mode. Press
-button for 1 sec. to “wake up” the time switch
.
1. Automatic-Mode: STOP = Deactivation slave-clock-line (SL)
2. Automatic-Mode: START = Activation slave-clock-line (SL)
3. Enter-Mode: To adjust the flashing digit. To scroll through a choice
DCF/GPS: The master clock receives the signal for the DCF77 time standard.
PIN: The time switch is locked; to unlock the device the PIN has to be entered.
1. To activate the time switch when operated without power supply.
2. Automatic-Mode: INFO NU (INFO SL) => Press OK [Info NU] to change the displayed
information while the device is in the Automatic-Mode.
3. Enter-Mode: To confirm the selection or the entered data.
SL stopped
The slave clocks receive no pulses from the master clock. The slave clocks are stopped. The missing pulses are stored.
After reactivation these pulses will be caught up.
SL running
Slave clocks are pulsed / clocked every minute
Exception SC53.17pro:
If you have selected minutes-line: Slave clocks are pulsed every minute
If you have selected seconds-line: Slave clocks are pulsed every second
RESET: Press all front keys for 2 seconds. The time switch is reset. The values for date
and time will be deleted and have to be re-entered. The switching program has not been
deleted!
SL adjust
Slave clocks will be adjusted till they show the time of the master clock (time correction / time synchronisation)
SL error
There is a power failure, overload or short circuit of the slave-clock-line (SL).
No pulses are sent to the slave-clock-line (SL).
Menu overview (Automatic-Mode / Enter-Mode)
DCF / GPS receiver
Summertime / Wintertime
*
Menu only available for master clocks with time switch functionality. For details please see the manual of the time switch:
SC 58.17 pro (DIN rail mounting) / SC 98.47 pro ( DIN rail mounting) / SC 53.17 pro (19”-housing) / SC 93.47 pro (19”- housing)
The device can process a DCF77-type telegram. The
antenna (receiver) is not included in delivery.
Initial operation of the antenna for DCF/GPS time
NOTE SAFETY INSTRUCTION!!
DISCONNECT POWER SUPPLY!!
Connect antenna as stated (manual of antenna)
Connect power supply
DCF-Symbol flashes (approx. 3 minutes)
DCF-Symbol appears static and synchronization
succeeded
Permanent blinking of DCF-Symbol = permitted signal no
reception possible (time base is the internal quartz)
No DCF-Symbol = antenna not connected
(time base is the internal quartz)
Adjustment of the atomic clock base:
Within menu
Options
->
DCF
an offset to GMT is already
configured and can be adjusted! Standard: GMT+1 => CET
The daylight saving time will be adjusted automatically
according to the selected settings (
Adjustments
->
Summertime:
(standard European rule))
Details daylights saving time slave clocks
With 60 additional pulses of 1 h. pulse suppression of the
slave-clock-line (SL).
Factory Defaults
Within the menu
Adjustments
->
Factory defaults
you
can reset the master clock to the state of delivery. Date,
time and switching program will be lost!
PIN-Code
Within the menu
Options
->
PIN-Code
the device can be
locked with a 4-digit PIN-Code. The code can be adjusted,
activated and deactivated. If you have forgotten the code
please call customer service.
Set and define slave-clock-line (SL) / Activate slave-clock-line (SL)
Exception SC 53.17 pro
The SC 53.17 pro has two slave-clock-lines!!!
Before entering the standard settings of the master clock (see on the left)
you have to confirm or adjust following line configurations:
INFO function
During regular operation (Automatic-Mode) different informations and adjustments of master clock and slave-clock-line can be displayed by pressing
.
After 1 minute the clock changes to standard display automatically!!!
If
SL error
is shown an info query is not possible. Please carry out corrective actions first!!!
NU = SL [slave-clock-line]
Error / Recovery system of the slave-clock-line (SL)
Failure: Slave clocks are 1 minute to late / Slave clocks are 1 minute to early
If there is a power failure, overload, short-circuit or incorrect wiring of the
slave-clock-line as well as a power failure of the slave-clock-power-
supply “
SL error
”
”
is displayed!!
Recovery system:
If “
SL error
”
”
is displayed no pulses are sent via slave-clock-line. The
complete quantity of suppressed pulses are saved and emitted
(
SL adjust
)
after corrective actions or power resumption (
SL running
).
If a slave clock is poled reversely the slave clocks are 1 minute late or early!!!
Corrective action:
!!ATTENTION!!
DANGER OF LIFE / RISK OF FIRE AND ELECTRIC SHOCK!!!
=> Installation and assembly of electrical equipment must be carried out only by a skilled person!!!
=> Disconnect device from power supply for wiring and installation purposes!!!
Stop slave-clock-line (SL)!! Press the -button [STOP]. „
SL stopped
“ is displayed.
Switch the corresponding wiring !!!PLEASE NOTE THE SAFETY INSTRUCTIONS!!!
Enter slave-clock-time
Activate slave-clock-line