ODU installation using the
basic fix mount kit;
(P/N 3004066-0002)
You may install the fixed mount on any structurally sound surface;
either on a horizontal, or vertical, or a sloped surface such as a roof
or wall.
1.
The pole has a 1.66” (4.2164cm) outer diameter (schedule 40
metal).
2.
The pole mount is 2lbs/0.9Kg. The azimuth/elevation bracket
is 1 lb/0.45Kg.
3.
The wall mounting pattern has four bolts in a 6” x 3 ¾”
(15.24cm x 9.525cm) rectangle.
The pole is shipped attached to the base bracket. Mount the base
bracket of this assembly to the structure with the appropriate
hardware (not included). Consult local building codes if needed.
Once the base bracket is mounted, perform the following steps
(refer to Figure 4-2 – Base Bracket and bubble level and Figure 4-3
– Pole Assembly):
1.
Insert the bubble level into the end of the pole (pipe) opposite
the base bracket. The bubble level fits inside the pole.
2.
Loosen the pole attachment fasteners at the base bracket so the
pole can swivel.
3.
Swivel the pole until the end of the pole where the ODU will
be installed is vertical. Adjust the pipe position until the
bubble is centered inside the circles on the top surface of the
bubble level.
4.
Tighten the pole attachment fasteners on the base bracket.
Figure 4-2 – Base Bracket and bubble level