Quick Disconnect Plug
In From Power Lead
The Wall Director
®
– WD18 Model
Installation Instructions
P.O. Box 60080 • 16555 East Gale Ave.
City of Industry, California 91716-0080
626/968-5666 • FAX 626/330-3861
WD18
Up and Down Models
IMPORTANT SAFETY INSTUCTIONS!
WARNING: Fixtures must be grounded in accordance with local codes or the National Electrical Code.
Failure to do so may result in serious personal injury.
CAUTION: Up and Down models are not interchangeable. Installing fixtures without regard to model designation
(UP or DOWN) could result in water intrusion, fixture damage, or lens breakage.
ATTENTION: All wiring must be done by a qualified electrician. KEEP THIS SHEET FOR FUTURE REFERENCE.
Part No. 95526
Revised 8/21/06 ECN 4877 Status 13
Quick Disconnect Plug
From Ballast Assembly
Quick Disconnect
Plugs Between
Socket and Reflector
Assembly (joined).
Fixture Housing
Field Wires
(by others)
Mounting Plate
(4)
J
"
Mounting
Hardware (by others).
Mounting Bolts
with Nuts (2)
Fixture Wires with
Disconnect Plug.
Reflector
Lens Frame
Reflector Hinge
Tabs
Attention:
If your fixture is equipped with a mulit-tap ballast and no voltage was specified on the purchase order, the
ballast has been wired for operation on a 277 volt circuit (347v in Canada). If other than 277 volts is required, i.e. 120V,
208V, 240V, connect incoming voltage lead to selected voltage lead on ballast. Cap off all unused leads.
!
Silicone Sealant
or Rope Caulk
Reflector Latch
Tools Required:
❑
Flat Blade Screwdriver
❑
5
⁄
32
" Allen Wrench
❑
Silicone Sealant
*
❑
Torque Wrench with 3" extension
❑
G
" Socket
Installation Instructions:
Make certain electrical supply is
OFF
before starting installation.
1. Install mounting bolts through backside of mounting plate making sure bolt heads seat in recessed hex and attach mounting
plate to wall surface with four (4)
J
"
bolts (by others), following the orientation label on mounting plate. Make sure the
mounting bolts on the mounting plate are level and that the nuts are flush with the ends of the mounting bolts after plate
is installed.
If mounting plate is embedded in concrete,
attach the two (2)
J
-
20 bolts (supplied) to threaded inserts on
mounting plate so that 1" of bolt thread is exposed. Discard the two (2)
J
-
20 bolts for surface mounted fixtures.
CAUTION: *Silicone sealant or rope caulk must be installed between mounting plate and mounting surface.
(continued on back)
!