Mini-Vault LTV 764
Installation Instructions
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
IMPORTANT SAFETY INSTRUCTIONS!
WARNING: Fixtures must be grounded in accordance with local codes or the National Electrical Code.
Failure to do so may result in serious personal injury. All work should be done by a qualified electrician.
SAFETY WARNING: Low voltage fixtures can become very hot depending on the lamp wattage used.
Lighted lamp is HOT! Glass lenses and metal areas above and around the lamp can become hot enough to
blister hands. Particular care should be taken not to locate fixtures where small children can reach them if
higher wattages are used. Do not use these fixtures in submersible installations such as fountains or swimming
pools. DO NOT operate luminaires with missing or damaged lens.
MAINTENANCE: To maintain light efficiency and prevent fixture overheating, glass lenses and enclosures must
be kept clean and free of dirt, dust, leaves, trash and mineral deposits from water. For optimum performance a
regularly scheduled maintenance program should be followed.
CAUTION: When relamping fixture avoid touching the lamp envelope with bare hands. If touching the lamp is
necessary during installation, clean the envelope with alcohol and dry with a clean, soft cloth before burning.
Contamination of the envelope may reduce lamp performance.
KEEP THIS SHEET FOR FUTURE REFERENCE.
Revised
7
/
16
/10 ECN 100715008 Status 9 Part No. 95596
1.
Excavate hole in desired location approximately 12”
in diameter and about 3” deeper than height of
fixture. Connect housing to conduit system using a
good thread sealant.
LTV764
CAUTION:
To help maintain a clean, dry splice compartment, seal the
conduit entries with RTV.
Do not exceed maximum wattage shown on fixture label.
2
.
Backfill hole with sand/gravel and soil for stability.
Do not backfill hole with bark or vermicolite. (May be
installed in concrete, for paved area installation use
Trim Ring, part no. TR60.)
Tools Required:
Make sure all electrical supply is
OFF
before beginning fixture installation.
Flat Head Screwdriver
F
” Hex Wrench
Thread Sealant
RTV Sealant
!
!
LAMP INFORMATION
Catalog. No Lamp Type Maximum Watts
LTV764
MR16
50
Halogen Integral Transformer
!
P.O. Box 60080 • 16555 East Gale Ave.
City of Industry, California 91716-0080
626/968-5666 • FAX 626/330-3861