2112 Fenton Logistic Park Blvd.
Fenton, MO 63026 USA
P/N KIL00921505 FORM NO. K1505 ECO6-040-20 R04/20
Page 1 of 4
KFLX SERIES LED LUMINAIRE
Luminaires are designed to be installed in Hazardous Locations: Class I, Division 2, Groups A, B, C and D; Class II,
Division 1, Groups E, F and G; Class III; T3C, T4, T4A, T5 or T6 (Class I, Div. 2); T3B, T3C (Class II, Div. 1); T3B, T3C
(Class I, Div 2 / Class II, Div. 1 Simultaneous Exposure); Type 4X; Marine Rated (US only); IP66.
);
Ambient 40C, 55C
and 65C where applicable
IEC Zone 2. IEC 60079-0:2017 IEC 60079-7:2015 +A1: 2018 and IEC 60079-31:2015 Zone 2 type of protection Ex ec
(increased safety), Zone 21 type of protection Ex tb (dust).
STANDARD VERSION
EMERGENCY VERSION
II 3G Ex ec IIC T5/T4/T3* Gc
II 3G Ex ec IIC T5/T4* Gc
II 2D Ex tb IIIC T160°C/T135°C/T100°C * Db
II 2D Ex tb IIIC T135°C Db
-40°C<Tamb<+65°C < 120W
-20°C<Tamb<+50°C
-40°C<Tamb<+40°C/+55°C > 120W
*Depending on wattage and ambient temperature
IECEx certificate IECEx QPS 19.0031X.
ATEX certificate Presafe 19 ATEX 32747X (ec) Presafe 19 ATEX 33512X(tb).
CAUTION:
Before installing, make sure you are compliant with area classifications, failure to do so may result in bodily injury, death
and property damage. Do not attempt installation until you are familiar with the following procedures. All installation must
comply with the applicable Electrical Code.
Make sure that the circuit is de-energized before starting installation or maintenance.
Verify that the installation is grounded. Failure to ground will create electrical shock hazards, which can cause serious
injury and or death.
IMPORTANT:
Technical information, advice and recommendations contained in these documents are based on information that Killark
believes to be reliable. All the information and advice contained in these documents is intended only for use by persons
having been trained and possessing the requisite skill and know-how and to be used by such persons only at their own
discretion and risk.
The nature of these instructions is informative only and do not cover all of the details, variations or combinations in which
this equipment may be used, its storage, delivery, installation, check out, safe operation, and maintenance. Since
conditions of use of the product are outside of the care, custody and control of Killark, the purchaser should determine the
suitability of the product for its intended use and assumes all risk and liability whatsoever in connection therewith.
ATTENTION:
Avant d’installer le luminaire, s’assurer que le luminaire est conforme à la classification des zones, le non- respect de
cette règle risque d’entraîner des dommages corporels et / ou matériels. Ne pas tenter d’entreprendre l’installation avant
d’être familiarisé avec les procédures suivantes. Toute installation doit être conforme au code électrique local et / ou
national et être effectuée par un électricien qualifié.
Veiller à ce que le circuit soit mis hors tension avant de commencer l’installation ou la maintenance.
Vérifier si le luminaire est mis à la terre. S’il n’est pas mis à la terre il pourrait causer des risques de choc électrique
susceptibles d’entraîner des blessures graves ou
la mort.