Pub. 42004-541A
Hands-free VoIP Telephone Manual
Page 8 of 24
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-541A.docx
02/20
Installation
General Information
WARNING
—This product can contain hazardous voltages. Always remove power to this
station and any associated equipment before beginning any installation.
CAUTION
—Do not install this equipment in areas other than those indicated on the approval
listing in the Approvals section of this manual. Such installation may cause a
safety hazard and consequent injury or property damage.
Install equipment without modification and according to all applicable local and national electrical codes.
Consult the National Electrical Code (NFPA 70), Canadian Standards Association (CSA 22.1), and local
codes for specific requirements regarding your installation. Class 2 circuit wiring must be performed in
accordance with the NEC.
Safety Guidelines
When installing any GAI-Tronics equipment, please adhere to the following guidelines to ensure the
safety of all personnel:
•
Do not install wiring during a lightning storm.
•
Electrostatic Discharge (ESD) Protection:
VoIP telephones may have an earth ground terminal
provision. If so, ensure that it is connected to ground in accordance with all local safety regulations
and the National Electrical Code (NEC). Grounding must be ensured for safe and stable
communications. Do not use long and coiled ground wires. Trim ground wires to the required
length. Use a star configuration whenever possible. Please note; proper grounding does not eliminate
the need for lightning protection for the telephone or the telephone system. A category 5 data line
lightning surge protector is recommended for telephones subject to any electrostatic discharge (e.g.
lightning).
•
Do not install jacks in wet locations unless the jack is specifically designed for wet locations.
Station Placement
Consider station placement and volume levels to prevent feedback problems in the system. To reduce
unpleasant feedback problems:
•
point each telephone away from other nearby telephones
•
reduce the volume levels
Security Hardware
The telephones described in this manual are vandal resistant. The front panel of each telephone covered
in this manual is attached to its enclosure with security screws. A GAI-Tronics Model 233-001 security
screwdriver or Torx T-25 security head tip (sold separately) is required to install the telephone.