Pub. 42004-467D
Camera Telephone Manual
Page 14 of 30
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-467D.docx
04/19
Polarity
Factory Setting
: Non-polarity sensitive
The telephone can be configured as polarity or non-polarity sensitive. The telephone operates regardless
of tip and ring polarity when configured for non-polarity. The telephone will only operate when the
telephone line’s positive terminal is connected to the tip terminal when configured for polarity. Use the
polarity sensitive setting to allow a line voltage reversal disconnect signal to disconnect the call.
•
Non-polarity Sensitive
: jumper
J6
in position
NON
•
Polarity Sensitive
: jumper
J6
on in position POL
DTMF Gain Select
Factory Setting
: Low gain selected
Two gain selections are available in the DTMF detection circuit. The low gain setting is recommended
for most installations. The high gain setting may be necessary if the telephone does not respond to
manual or TMA-generated DTMF commands.
•
Low Gain Selected
: jumper
J17
in position
LO
•
High Gain Selected
: jumper
J17
in position HI
Password Enable/Disable
Factory Setting
: Password enabled
This telephone can be configured to enable or disable the password protection for programming (standard
mode only). This can be useful when initially programming the telephones.
•
Password Enabled
: jumper
J9
jumper in position
EN
•
Password Disabled
: jumper
J9
in position DIS
Command Select
Factory Setting: Auto
Jumper
J20
enables or disables the automatic transition to SMART operation. SMART operation is
disabled when the jumper in the
STD
position.
•
SMART Operation Enabled (Auto)
: jumper
J20
in position
AUTO
•
SMART Operation Disabled (Standard)
: jumper
J20
in position STD
Low-Power Mode
Factory Setting
: Low-power mode disabled
The performance of the telephone may be improved for installations with minimal loop current available
by enabling this feature. Symptoms of minimal loop current may include low speaker volume and/or
momentary muting of audio. The low-power mode should be disabled in most applications. The low-
power mode is enabled by installing the following three jumpers:
J21
,
J22
, and
J23
.
•
Low-Power Mode Enabled
: jumpers installed at
J21
,
J22
, and
J23
•
Low-Power Mode Disabled
: jumpers
NOT
installed at
J21
,
J22
, and
J23