background image

Pub. 42004-547A 

NEMA 4X VoIP Telephones 

Page 6 of 17

 

P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-547A.docx 

03/20 

Security Hardware

 

Model 354-71x Series Telephones are vandal-resistant; the front panel is attached to the enclosure with 
security screws.  A GAI-Tronics Model 233-001 Security Screwdriver (sold separately) or Torx T-25 
security head tip (included with the telephone) is required to install the security screws. 

Conduit Installation

 

GAI-Tronics recommends installing telephone cable in conduit to protect against damage and vandalism.  
Mounting and wiring the Model 354-71x Series telephones must be in accordance with installation 
standard practices. 

Entering the enclosure from the top is not recommended.  Bottom (preferred) or side entry helps prevent 
condensation moisture from dripping onto the telephone electronics.  If using conduit, an appropriate hub 
(Myers STG Series recommended) or a UL Listed NEMA 4X rated connector appropriate for the 
installation should be used.  If a top entry must be made, a drip path is strongly recommended.  Seal all 
conduit entrances around the entry points and inside the conduit using a silicone-type sealant. 

The Model 354-71x Series Telephones are not supplied with openings for conduit or cable.  Conduit 
entrances must be created prior to mounting the enclosure to the wall surface. 

1.

 

Open the door and remove the front panel assembly (carefully set aside). 

2.

 

Drill (hole saw) or punch entry openings. 

There must be a minimum of 1 inch (26 mm) of material between entry holes. 

1.

 

Install hubs or fittings. 

Mount the Enclosure

 

Mount the enclosure using the four 0.437-inch (11mm) diameter holes located on the mounting flanges 
with 3/8-inch (M8) hardware  (see Figure 4)

 

The recommended entry is via the enclosure bottom to prevent moisture from dripping onto the 
connection terminals. 

 

Use caution to avoid damaging the internal components when mounting the enclosure. 

 

The suggested mounting height is 48 inches (1219 mm) to the center of the bottom mounting holes of 
the enclosure. 

Содержание GAI-TRONICS NEMA 4X 354-710

Страница 1: ...xternal 3 Internal 3 System Requirements and Limitations 4 VoIP Subscriber Tips 4 Operation 4 Handset Receiver Volume Control 4 Model 354 710 Handset Operation 4 Model 354 711 Auto dial Handset Operat...

Страница 2: ...itoring and Reporting 13 Maintenance 13 Service 13 USB port 13 Troubleshooting 14 Status Indication 14 Power 14 Heartbeat 14 Link 14 Speed 14 VoIP Circuit PCBA Pushbuttons 15 Reset 15 Factory 15 Repla...

Страница 3: ...quire a direct water spray hose down for cleaning purposes or where a non corrosive material is required The 354 71x Series telephone is perfectly suited for areas considered too harsh for a standard...

Страница 4: ...11RD NEMA 4X VoIP Auto dial Telephone Red Feature and Functions GAI Tronics VoIP telephones include the following features NEMA 4X rated with door closed NEMA 3R with door open handset with 6 foot Hyt...

Страница 5: ...me control push button and ringer The handset rests on a cradle that has a magnetic reed switch to signal an off hook condition see Figure 2 Figure 2 NEMA 4X VoIP Telephone Internal The Model 354 71x...

Страница 6: ...nderstanding of any limitations of the local 911 service Be aware that VoIP telephone services may not work if the power is out or the Internet connection is down Consider installing a backup power su...

Страница 7: ...ta line lightning surge protector on any phone installed where the phone or phone cable is at risk of exposure to lightning strikes The lightning arrestor must be installed as close to the phone as po...

Страница 8: ...a UL Listed NEMA 4X rated connector appropriate for the installation should be used If a top entry must be made a drip path is strongly recommended Seal all conduit entrances around the entry points a...

Страница 9: ...Pub 42004 547A NEMA 4X VoIP Telephones Page 7 of 17 P Standard IOMs Current Release 42004 Instr Manuals 42004 547A docx 03 20 Figure 4 Mounting and Conduit Entry Locations...

Страница 10: ...he panel Figure 5 Installation and Maintenance Configuration Field Wiring Pull the required field cables into the rear enclosure and install the connections as indicated in the following subsections s...

Страница 11: ...ct power to the system as indicated in the POE equipment manual Power Mode A Class 0 Local Power A separate isolated 24 to 48 volt dc power supply is required when PoE is not available see Table 7 on...

Страница 12: ...stomer use Terminate these inputs to terminal block P12 on the VoIP Carrier PCBA see Figure 6 Connect each input between the desired input INPUT 1 4 and common GND on terminal block P12 Table 4 Auxili...

Страница 13: ...nel on the rear enclosure 2 Do not to pinch any cables 3 Secure the front panel using the four screws and washers provided 4 Torque the screws to 10 12 in lb 1 13 1 36 N m Programming The network conf...

Страница 14: ...within a single unit Configuration files are ASCII text files containing configuration options that can be read and edited by a knowledgeable user The telephone can automatically download a configurat...

Страница 15: ...handset integrity loop configuration error cold reset power cycle warm reset internal command keypad error such as a stuck button if applicable key hook off hook status register fail unsuccessful SIP...

Страница 16: ...perly configured Cannot make or receive calls Check the connection of the LAN cable Verify that power is applied to the unit Verify the LAN parameters have been configured properly Verify the telephon...

Страница 17: ...Figure 7 The telephone maintains the current configuration Figure 7 VoIP PCBA Indicators and Buttons Factory Use the FACTORY button see Figure 7 to erase the current configuration and restore the fac...

Страница 18: ...240 V ac input 24 V dc output Reference Documentation VoIP Basic Configuration Guide 42004 548 VoIP Programming Manual 502 20 0171 001 Specifications Electrical Power Requirements Input voltage dc po...

Страница 19: ...rd G style handset Hytrel standard Connection RJ45 jack Dimensions outside VoIP 14 6 H 10 9 W 10 5 D in 371 276 267 mm Mounting wall or column four 0 44 inch 11 mm diameter mounting holes Shipping wei...

Страница 20: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: