background image

Pub. 42004-547A 

 

G A I - T R O N I C S

®

 

A   H U B B E L L   C O M P A N Y  

NEMA 4X VoIP Telephones 

GAI-TRONICS  3030 KUTZTOWN RD.  READING, PA  19605 USA 

610-777-1374  

  800-492-1212  

  Fax:  610-796-5954 

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

 

Confidentiality Notice 

This manual is provided solely as an installation, operation, and maintenance guide and contains sensitive 
business and technical information that is confidential and proprietary to GAI-Tronics.  GAI-Tronics 
retains all intellectual property and other rights in or to the information contained herein, and such 
information may only be used in connection with the operation of your GAI-Tronics product or system.  
This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third 
party. 

General Information 

The GAI-Tronics Model 354-71x Series 
NEMA 4X VoIP telephones are designed for 
use in extreme weather conditions where 
temperature and moisture are a concern.  They 
are also ideal for use in areas that require a 
direct water spray (hose-down) for cleaning 
purposes or where a non-corrosive material is 
required. 

The 354-71x Series telephone is perfectly 
suited for areas considered too harsh for a 
standard telephone. 

The 354-71x Series telephone operates in the 
same manner as a standard telephone; simply 
lift the handset, listen for a dial tone, and dial 
the desired telephone number.  If the 
telephone is an autodial model, simply lift the 
handset and the pre-programmed number is 
automatically dialed. 

The 354-71x Series telephones are designed for connection to a 10/100 Base-T Ethernet network, and 
operate with PoE (Power-over-Ethernet) or a local 24 to 48 V dc power source.  The VoIP telephones 
provide point-to-point communications between personnel throughout a facility over an existing LAN. 

In addition to providing standard telephone operation, the NEMA 4X VoIP telephones provide real-time 
alarm reporting via syslog, SNMP, or TMA (Telephone Management Application).  This allows 
supervision of the telephones’ activity to support addressing caller needs or maintenance issues 
immediately.  There are also configurable inputs and outputs available in all models. 

 

Figure 1  Model 354-710 Series NEMA 4X VoIP 

Telephone 

Содержание GAI-TRONICS NEMA 4X 354-710

Страница 1: ...xternal 3 Internal 3 System Requirements and Limitations 4 VoIP Subscriber Tips 4 Operation 4 Handset Receiver Volume Control 4 Model 354 710 Handset Operation 4 Model 354 711 Auto dial Handset Operat...

Страница 2: ...itoring and Reporting 13 Maintenance 13 Service 13 USB port 13 Troubleshooting 14 Status Indication 14 Power 14 Heartbeat 14 Link 14 Speed 14 VoIP Circuit PCBA Pushbuttons 15 Reset 15 Factory 15 Repla...

Страница 3: ...quire a direct water spray hose down for cleaning purposes or where a non corrosive material is required The 354 71x Series telephone is perfectly suited for areas considered too harsh for a standard...

Страница 4: ...11RD NEMA 4X VoIP Auto dial Telephone Red Feature and Functions GAI Tronics VoIP telephones include the following features NEMA 4X rated with door closed NEMA 3R with door open handset with 6 foot Hyt...

Страница 5: ...me control push button and ringer The handset rests on a cradle that has a magnetic reed switch to signal an off hook condition see Figure 2 Figure 2 NEMA 4X VoIP Telephone Internal The Model 354 71x...

Страница 6: ...nderstanding of any limitations of the local 911 service Be aware that VoIP telephone services may not work if the power is out or the Internet connection is down Consider installing a backup power su...

Страница 7: ...ta line lightning surge protector on any phone installed where the phone or phone cable is at risk of exposure to lightning strikes The lightning arrestor must be installed as close to the phone as po...

Страница 8: ...a UL Listed NEMA 4X rated connector appropriate for the installation should be used If a top entry must be made a drip path is strongly recommended Seal all conduit entrances around the entry points a...

Страница 9: ...Pub 42004 547A NEMA 4X VoIP Telephones Page 7 of 17 P Standard IOMs Current Release 42004 Instr Manuals 42004 547A docx 03 20 Figure 4 Mounting and Conduit Entry Locations...

Страница 10: ...he panel Figure 5 Installation and Maintenance Configuration Field Wiring Pull the required field cables into the rear enclosure and install the connections as indicated in the following subsections s...

Страница 11: ...ct power to the system as indicated in the POE equipment manual Power Mode A Class 0 Local Power A separate isolated 24 to 48 volt dc power supply is required when PoE is not available see Table 7 on...

Страница 12: ...stomer use Terminate these inputs to terminal block P12 on the VoIP Carrier PCBA see Figure 6 Connect each input between the desired input INPUT 1 4 and common GND on terminal block P12 Table 4 Auxili...

Страница 13: ...nel on the rear enclosure 2 Do not to pinch any cables 3 Secure the front panel using the four screws and washers provided 4 Torque the screws to 10 12 in lb 1 13 1 36 N m Programming The network conf...

Страница 14: ...within a single unit Configuration files are ASCII text files containing configuration options that can be read and edited by a knowledgeable user The telephone can automatically download a configurat...

Страница 15: ...handset integrity loop configuration error cold reset power cycle warm reset internal command keypad error such as a stuck button if applicable key hook off hook status register fail unsuccessful SIP...

Страница 16: ...perly configured Cannot make or receive calls Check the connection of the LAN cable Verify that power is applied to the unit Verify the LAN parameters have been configured properly Verify the telephon...

Страница 17: ...Figure 7 The telephone maintains the current configuration Figure 7 VoIP PCBA Indicators and Buttons Factory Use the FACTORY button see Figure 7 to erase the current configuration and restore the fac...

Страница 18: ...240 V ac input 24 V dc output Reference Documentation VoIP Basic Configuration Guide 42004 548 VoIP Programming Manual 502 20 0171 001 Specifications Electrical Power Requirements Input voltage dc po...

Страница 19: ...rd G style handset Hytrel standard Connection RJ45 jack Dimensions outside VoIP 14 6 H 10 9 W 10 5 D in 371 276 267 mm Mounting wall or column four 0 44 inch 11 mm diameter mounting holes Shipping wei...

Страница 20: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...