E3 Fault Reporting
RTU Fault Mode
—specifies the reporting level at which the RTU-related faults are reported by the
system.
Audio Fault Mode
—specifies the reporting level at which any audio-related faults are reported by the
system.
Station Fault Mode
—specifies the reporting level at which any station faults are reported by the system.
RTU Settings (Excluding SVS)
Figure 115. RTU Settings (Excluding SVS) Pane
RTU RS IO
RTU IN 1
&
RTU IN 2
—specifies the normal operating mode (OFF, NO, NC, NO_S, NC_S, MNO_S,
SB_S, HV_S). The available options are limited to the station’s valid options at the station level of the
configuration. All options are available at the remaining configuration levels.
RTU OUT
—specifies what activates the RTU output on the station.
RS IN 1
&
RS IN 2
—specifies the remote station inputs as NO (normally open), or NC (normally
closed).
RTU Triggering
RTU IN 1 Trigger and RTU IN 2 Trigger
— specifies the action taken or triggered when the RTU input
is activate. Selections include: Global Mutes, ACKs, CANCELs, and E3 events.
RTU OUT Timer
—specifies the RTU output period. Enter zero to activate the RTU output for the
duration of the trigger.
RTU Inhibiting
RTU IN 1 Inhibit
&
RTU IN 2 Inhibit
—specifies the inhibit groups that affect the RTU inputs (see the
Inhibit Groups section).