Miscellaneous Pane
Figure 114. Miscellaneous Parameters Pane
Diagnostics
—determines if the handset, headset, and/or the speaker are tested each time the diagnostic
self- test runs. Set this to
HANDSET
+
HEADSET
+
SPEAKER
to execute all diagnostics, any
combination of the three, or OFF.
Valid settings: OFF, HANDSET, H HEADSET, SPEAKER,
H SPEAKER
,
H SPEAKER, H H SPEAKER.
LED Triggering Parameters
LED1–LED5
—Configure each LED to turn on during various station conditions (see the I/O States
section).
Other
E-Z All Call
—only valid on handset stations equipped with an
A
LL
C
ALL
paging pushbutton. This
parameter determines whether the handset pressbar must be pressed when making a page to the
PAGETX_B_SOCK
multicast socket. Valid values are:
•
TRUE—Only the
A
LL
C
ALL
button needs to be pressed after lifting the handset to start paging to
the
PAGETX_B_SOCK
multicast address. The handset pressbar does not need to be pressed to
initiate the page. Pressing the handset pressbar without holding the
A
LL
C
ALL
button will initiate
a page on
PAGETX_A_SOCK
.
•
FALSE
—The handset pressbar must always be pressed to make a page; including the use of the
A
LL
C
ALL
button.
N
OTE
:
Do not set this parameter to TRUE on stations that do not have an
A
LL
C
ALL
button.
Hookswitch Invert
— This parameter enables the inversion of the current physical state of the hook-
switch represented by the ON-HOOK and OFF_HOOK variables. Valid settings are:
•
TRUE—ON-HOOK and OFF-HOOK values are reversed.
•
FALSE
—ON-HOOK and OFF-HOOK values are represent the actual current state of the
handset.
Handset Timeout
—limits the period that a station is off hook. This parameter is configured in minutes
with a default of eight minutes. A setting of zero disables the hookswitch timeout.
Pressbar Timeout
—limits the period that a page can continue. This parameter is configured in minutes
with a default timeout of two minutes. A setting of zero disables the pressbar timeout.