Hubbell GAI-Tronics 351-715 Скачать руководство пользователя страница 3

Pub. 42004-500C 

 

G A I - T R O N I C S

®

  C O R P O R A T I O N  

A   H U B B E L L   C O M P A N Y  

Division 2 VoIP Page Phones  

Wired and WiFi 

GAI-Tronics Corporation  3030 Kutztown Road  Reading, PA  19605  USA 

610-777-1374  

  800-492-1212  

  Fax:  610-796-5954 

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

 

Confidentiality Notice 

This manual is provided solely as an installation, operation, and maintenance guide and contains sensitive 
business and technical information that is confidential and proprietary to GAI-Tronics.  GAI-Tronics 
retains all intellectual property and other rights in or to the information contained herein, and such 
information may only be used in connection with the operation of your GAI-Tronics product or system.  
This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third 
party. 

General Information 

GAI-Tronics’ Class I, Division 2 VoIP Page Phones are constructed of durable glass-reinforced 
engineered plastic and are weatherproof rated NEMA 4X.  The built-in Class D paging amplifier provides 
up to 30 watts of speaker output, allowing multicast broadcast page announcements over speakers 
connected to the phone’s amplifier output.  Autodial 
telephone models dial a preprogrammed number 
when the handset is lifted from the cradle. 

GAI-Tronics’ VoIP Page Phones are available in 
wired and wireless versions with two model types, 
handset and handset with auxiliary jack.  Both model 
types have three input power options (see the model 
chart in Table 1). 

Div. 2 VoIP Page Phones connect to a 10/100 BaseT 
Ethernet network.  An external ac or dc power source 
is required for full audio power operation.  Power-
over-Ethernet (PoE) models do not require additional 
power but have limited speaker output. 

WiFi models connect to a WLAN (wireless local area 
network) meeting the IEEE 802.11 a/b/g/n standard.  
An external ac or dc power source is required for 
operation. 

Div. 2 VoIP Page Phones also provide real-time 
alarm reporting. This enables monitoring the telephones’ activity to address caller needs or maintenance 
issues immediately.  There are also configurable inputs and outputs available in all models. 

 

Figure 1.  Model 351-8

xx

 Div. 2  

VoIP WiFi Page Phone 

Содержание GAI-Tronics 351-715

Страница 1: ...iption 4 External 4 Internal 5 System Requirements and Limitations 6 VoIP 6 VoIP WiFi 6 Multicast Broadcasting 6 VoIP Subscriber Tips 7 Operation 7 Handset Receiver Volume Control 7 Handset Operation...

Страница 2: ...ndset Receiver Level Remote Control 17 Input Contacts 17 Output Contacts 18 Maintenance 18 Monitoring and Reporting 18 Status Indication 19 Power 19 Heartbeat 19 Link 19 Speed 19 WiFi Activity WiFi Un...

Страница 3: ...d NEMA 4X The built in Class D paging amplifier provides up to 30 watts of speaker output allowing multicast broadcast page announcements over speakers connected to the phone s amplifier output Autodi...

Страница 4: ...Div 2 VoIP WiFi AC Page Phone with Relay 351 824 Div 2 VoIP WiFi DC Page Phone with Relay Handset with Auxiliary Jack Models Model Description 351 715 Div 2 VoIP AC Page Phone 351 725 Div 2 VoIP DC P...

Страница 5: ...ired 7 Wifi 8 AC 1 DC 2 POE 3 Page Phone 3 Page Phone with Relay 4 Page Phone with Auxiliary Jack 5 Page Phone with Auxiliary Jack and Relay 6 Orange 1 Gray 2 Yellow 3 Red 4 None 0 6 Feet 1 15 Feet 2...

Страница 6: ...A Class 0 configurable via web page or download four configurable auxiliary inputs two configurable dry contact outputs relay units only Hardware Description External These Division 2 VoIP Page Phones...

Страница 7: ...headset adapter PCBA and keypad PCBA are mounted to the front cover Amplifier only versions do not include a keypad PCBA see Figure 3 Model 351 8xx VoIP WiFi Page Phones The power supply input power...

Страница 8: ...y in a peer to peer configuration without the need for a LAN connection Systems containing three or more WiFi telephones or a combination of WiFi and hardwired connected VoIP telephones require a wire...

Страница 9: ...button switch located on the front panel to adjust the handset receiver volume The volume decreases from 20 dB to 12 dB to 0 dB and back up to 20 dB of the original signal with each button press The...

Страница 10: ...nduit entries Install a Cat5 data line lightning surge protector on any phone installed where the phone or phone cable is at risk of being exposed to lightning strikes The lightning arrestor must be i...

Страница 11: ...sures is 48 inches 1219 mm to the center of the bottom mounting holes of the enclosure Class I Division 2 VoIP Page Phones are not supplied with conduit or cable openings 2 Remove the front panel 3 Dr...

Страница 12: ...crews from the power supply cover located in the rear enclosure and remove the power supply cover 2 Connect the incoming power conductors to the 3 point terminal block in the rear enclosure see the Lo...

Страница 13: ...conductor No 22 AWG is typical Output contacts two conductor No 18 AWG is typical Speaker two or three conductor No 18 AWG is typical Figure 7 Internal PCBA Connections NetworkCable Connect a Categor...

Страница 14: ...ommon COM on terminal block P12 see Table 4 The inputs are configurable See the Inputs section of GAI Tronics Pub 42004 548 for configuration instructions see the Reference Documentation section Table...

Страница 15: ...ions using the SIP protocol between the desired locations before attempting to configure the GAI Tronics VoIP Telephones First Time WiFi Interface Setup Setup the WiFi interface to configure the telep...

Страница 16: ...tton The web page will show Set Successfully Restart to use new setting 6 Restart to use the new setting and then click on the STA Interface Setting selection The STA INTERFACE SETTING web page opens...

Страница 17: ...k and click the APPLY button The AP s SSID security mode and encryption type fields will be filled in when the STA interface setting webpage opens again NOTE Manually enter the AP s SSID security mode...

Страница 18: ...Interface Use this procedure to erase the current WiFi configuration in the telephone and configure the WiFi adapter with the factory default settings 1 Press the RLOAD button for 10 seconds to reset...

Страница 19: ...ings within a single unit Configuration files are ASCII text files containing configuration options that can be read and edited by a knowledgeable user The telephone can automatically download a confi...

Страница 20: ...also be set in some modes Refer to Pub 42004 548 for programming instructions for the outputs see the Reference Documentation section Maintenance Monitoring and Reporting Each telephone can recognize...

Страница 21: ...a is being transmitted see Figure 13 WiFiReady WiFiUnitsOnly The WiFi READY LED is a green LED located on the RJ 45 connecter J2 on the VoIP carrier PCBA It illuminates when the WiFi Interface is read...

Страница 22: ...n Authorization Number will be issued if service is required Equipment must be shipped prepaid to GAI Tronics with an RA and a purchase order number Repairs or a replacement will be made in accordance...

Страница 23: ...y configured outputs not operational Check the output connections Verify the outputs are properly configured cannot make or receive calls Check the connection of the LAN cable Verify that power is app...

Страница 24: ...liant Loose routing call control signaling WiFi Network Standards IEEE 802 11b g n Frequency 2 412 GHz to 2 484 GHz Configuration embedded web server configuration file download password protection Au...

Страница 25: ...ly WiFi Activity WiFi Ready WiFi Connected LEDs Monitoring and reporting real time over TCP IP proprietary syslog application SNMP TMA automatic fault reporting Environmental Operating temperature 4 F...

Страница 26: ...sted and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when...

Страница 27: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: