Hubbell GAI-TRONICS 227-003 Скачать руководство пользователя страница 1

Pub. 42004-350E

GAI-Tronics Corporation  P.O. Box 1060, Reading, PA  19607-1060  USA

610-777-1374  

„

  800-492-1212  

„

  Fax:  610-796-5954

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

G A I - T R O N I C S ®   C O R P O R A T I O N

A   H U B B E L L   C O M P A N Y

Models 227-003, 257-003, and 277-003

Auto-dial S.M.A.R.T. Phones

T

A B L E   O F  

C

O N T E N T S

Getting Started ................................................................................................................................1

Product Overview ................................................................................................................................... 1

Standard Operation ................................................................................................................................ 2

Volume Control Button ........................................................................................................................................2
To Receive a Call..................................................................................................................................................2
To Place a Call......................................................................................................................................................2

Installation ......................................................................................................................................3

Safety Guidelines..................................................................................................................................... 3

General Installation Guidelines ............................................................................................................. 3

Tamper-Resistant Hardware .................................................................................................................................3
Conduit Installation Details ..................................................................................................................................3

Model 227-003 ......................................................................................................................................... 5

Model 257-003 ......................................................................................................................................... 7

Model 277-003 ......................................................................................................................................... 9

Stanchion or Flush-mount Applications ...............................................................................................................9
Surface Mount Applications ...............................................................................................................................10

Setup ..............................................................................................................................................11

Hardware Configuration...................................................................................................................... 11

Auto-answer Configuration ................................................................................................................................11
Polarity Configuration ........................................................................................................................................11

Programming......................................................................................................................................... 13

Enter the Programming Mode.............................................................................................................................13
Basic Programming Commands .........................................................................................................................14

Maintenance..................................................................................................................................16

Specifications ................................................................................................................................17

Confidentiality Notice ...................................................................................................................20

Содержание GAI-TRONICS 227-003

Страница 1: ...ct Overview 1 Standard Operation 2 Volume Control Button 2 To Receive a Call 2 To Place a Call 2 Installation 3 Safety Guidelines 3 General Installation Guidelines 3 Tamper Resistant Hardware 3 Condui...

Страница 2: ...hone The enclosure for this phone is made of weatherproof high impact glass reinforced polyester and can be equipped with a spring loaded door 277 003 Flush panel Auto dial S M A R T Phone This is a f...

Страница 3: ...the handset volume Each press of the button increases the volume in four steps and then returns it to the original setting in a circular fashion ToReceiveaCall When the telephone rings 1 Lift the han...

Страница 4: ...sulated telephone wires or terminals unless the telephone line has been disconnected at the network interface The Model 40404 045 Power Supply must be connected to an ac source within 4 feet of the te...

Страница 5: ...ls 42004 350e doc 02 05 Please refer to Figure 1 and Figure 2 as examples of recommended conduit installation details NOTE See page 5 for the Model 227 003 Telephone Figure 1 Bottom entry conduit inst...

Страница 6: ...en using the Model 232 Pole Mounting Kit 3 Insert four hole plugs provided in the unused holes 4 Position the enclosure on the mounting surface and secure it with four fasteners The holes in the telep...

Страница 7: ...he half modular telephone cord through the conduit Figure 5 Model 227 003 Mounting Details 7 Replace the front panel assembly and secure using the eight front panel tamper resistant screws 8 Connect t...

Страница 8: ...ear enclosure Mount the enclosure on the wall using four 20 machine screws with nuts and washers or 14 wood screws of appropriate length for the mounting surface 4 Drill a 0 688 diameter hole at eithe...

Страница 9: ...PAGE 8 of 20 AUTO DIAL S M A R T PHONES Pub 42004 350E s_eng gtcproddocs standard ioms current release 42004 instr manuals 42004 350e doc 02 05 Figure 7 Model 257 003 Mounting Details...

Страница 10: ...d outdoors install the telephone line suppressor customer supplied on the telephone line 3 Remove the tapered plug from the top or bottom cable entry hole in the back box and install the telephone lin...

Страница 11: ...ting surface for an effective perimeter seal This is particularly important if the mounting surface is uneven 3 Install the telephone line suppressor customer supplied on the telephone line if applica...

Страница 12: ...r on pins 2 and 3 Disable Insert the J14 jumper on pins 1 and 2 Do not use this setting except under the direction of GAI Tronics personnel NOTE The Auto answer feature must be enabled during remote p...

Страница 13: ...PAGE 12 of 20 AUTO DIAL S M A R T PHONES Pub 42004 350E s_eng gtcproddocs standard ioms current release 42004 instr manuals 42004 350e doc 02 05 Figure 10 S M A R T Phone PCBA...

Страница 14: ...your programming information written down allows you to enter the key sequence at a steady pace This is important because the programming sequence times out if there is a pause of more than two second...

Страница 15: ...to program these three auto dial numbers The three auto dial telephone numbers are labeled as 11 primary 12 first roll over and 13 second roll over You may program these for three different numbers o...

Страница 16: ...sents the number of half second increments of duration Entering 0 results in a call time out of 4 5 hours Enter 37 120 32400 to assign a time limit or change an existing time limit 37 Data transfer co...

Страница 17: ...chedule auto dial maintenance calls to alert maintenance personnel of any unusual sensor or fault conditions that exist S M A R T Phones can also be programmed to generate an auto dial maintenance cal...

Страница 18: ...cord G style with 19 inch armored cord and internal lanyard Dimensions 13 50 H 9 70 W 6 15 D inches Mounting Eight 0 39 inch diameter holes Weight 14 5 lbs Model 257 003 Construction High impact glass...

Страница 19: ...C Certification Number 882B GTC S M A R T Ringer Equivalence Number 4B Connection Method CA11A Replacement Parts Part No Description 227 003 257 003 277 003 233 Model 233 Tamper Resistant Screwdriver...

Страница 20: ...uipment GAI Tronics telephone for repair or warranty information please contact GAI Tronics Corporation at 800 492 1212 or www gai tronics com If the equipment is causing harm to the telephone network...

Страница 21: ...nce guide and contains sensitive business and technical information that is confidential and proprietary to GAI Tronics GAI Tronics retains all intellectual property and other rights in or to the info...

Страница 22: ...be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Warranty Periods Every...