Pub. 42004-519C
Rugged VoIP Autodial Handset Telephones
Page 20 of 26
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-519C.docx
10/19
Outputs
Two outputs have been provided for customer use. Terminations for these outputs are provided on
connector
P10
.
Table 5. Output Contacts
—
Connector P10
Pin
Label
Description
1
C1
Common Output 1
2
NO1
Normally Open Output 1
3
C2
Common Output 2
4
NO2
Normally Open Output 2
Programming
The network configuration must provide VoIP service (using the SIP protocol) between the desired
locations before attempting to configure a GAI-Tronics VoIP telephone.
The general sequence to set up a VoIP telephone is as follows:
VoIP PCBA Setup
1.
Connect a PC to the same network as the VoIP telephone.
2.
Log into the unit’s web interface.
The unit is factory configured with a static IP address:
192.168.1.2.
3.
Enter the user name and password when prompted.
The initial factory settings are:
•
U
SER
N
AME
:
user
•
P
ASSWORD
:
password
4.
Change the user name and password upon first login.
This security measure helps to prevent unauthorized changes to the VoIP telephone’s interface
configuration.
VoIP PCBA Initial Network Configuration
Each VoIP PCBA must be set up for the network prior to installation. Assign a local ID, domain, proxy,
and registrar.
Assign a host name
Host names provide identification of different VoIP PCBAs on the network.
Test
Verify that calls can be made successfully.
Maintain
Monitor alarms. Set up auto-updates.