background image

Pub. 42004-445L 

 

G A I - T R O N I C S

®

 

A   H U B B E L L   C O M P A N Y  

Rugged VoIP Handset Telephones

 

T

A B L E   O F  

C

O N T E N T S

 

GAI-Tronics Corporation  3030 Kutztown Road  Reading, PA  19605  USA 

610-777-1374  

  800-492-1212  

  Fax:  610-796-5954 

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

 

Confidentiality Notice .....................................................................................................................1

 

Product Overview ............................................................................................................................1

 

Features and Functions .......................................................................................................................... 2

 

System Requirements and Limitations ................................................................................................. 2

 

Tips for VoIP Subscribers ...................................................................................................................... 2

 

Operation .........................................................................................................................................2

 

Place a Call .............................................................................................................................................. 2

 

Receive a Call .......................................................................................................................................... 3

 

Handset Receiver Volume Control ........................................................................................................ 3

 

Monitor and Report Telephone Status .................................................................................................. 3

 

Status Indication ..................................................................................................................................... 3

 

Power .................................................................................................................................................... 3 
Heartbeat ............................................................................................................................................... 3 
EACT .................................................................................................................................................... 3 

Installation ......................................................................................................................................4

 

Safety Guidelines ..................................................................................................................................... 4

 

Security Hardware .................................................................................................................................. 4

 

Conduit Installation Details (Applicable to Models 246-700 and 256-700) ........................................ 4

 

Models 210-700BH and 210-700BHAC ................................................................................................. 5

 

Model 226-700 ......................................................................................................................................... 7

 

Model 246-700 ......................................................................................................................................... 9

 

Model 256-700 ....................................................................................................................................... 11

 

Model 276-700 ....................................................................................................................................... 13

 

Models 276-702BH and 276-702BHAC ............................................................................................... 15

 

Flush Mount Installation ..................................................................................................................... 15 
Surface-Mount Installation using the No. 238-003 Enclosure ............................................................ 17 

Field Wiring ..................................................................................................................................17

 

Recommended Cabling ......................................................................................................................... 17

 

Power ...................................................................................................................................................... 18

 

Power-Over-Ethernet .......................................................................................................................... 18 
Local Power ........................................................................................................................................ 18 
Ground (For Models 210-700BH/-700BHAC, 226-700, 276-700/-702BH/-702BHAC Only) .......... 19 

Network .................................................................................................................................................. 19

 

Содержание GAI-TRONICS 210-700BH

Страница 1: ...ceive a Call 3 Handset Receiver Volume Control 3 Monitor and Report Telephone Status 3 Status Indication 3 Power 3 Heartbeat 3 EACT 3 Installation 4 Safety Guidelines 4 Security Hardware 4 Conduit Ins...

Страница 2: ...P PCBA Initial Network Configuration 20 VoIP Telephone Input Contacts 21 VoIP Telephone Output Contacts 21 Maximum Handset Receiver Level Remote Control 21 Maintenance 21 General Information 21 Preven...

Страница 3: ...munications between personnel throughout a facility over an existing LAN The following VoIP Telephones are detailed in this manual Table 1 Model Chart Model Description 210 700BH Surface mount VoIP Be...

Страница 4: ...an interconnected VoIP service provider the following points should be addressed Provide accurate physical address information to the VoIP service provider to ensure that emergency services can quick...

Страница 5: ...generate several hardware and configuration fault condition alarms These alarms can be signaled to a remote site using three methods syslog output over TCP SMTP mail message TMA Telephone Management...

Страница 6: ...ble communications Do not use long and coiled ground wires Trim ground wires to the required length Use a star configuration whenever possible Please note proper grounding does not eliminate the need...

Страница 7: ...als 42004 445L docx 10 19 Figure 1 Model 246 700 256 700 Bottom entry conduit installation details Figure 2 Model 246 700 256 700 Top entry conduit installation details NOT RECOMMENDED Models 210 700B...

Страница 8: ...omer supplied 4 Two 1 inch diameter entry holes are provided on the mounting panel for cable entry see Figure 3 Pull the Ethernet cable through one of the two holes and install the cable see the Field...

Страница 9: ...the mounting surface and secure it with four fasteners The holes in the telephone enclosure accept 3 8 inch screws or bolts The Model 232 001 Pole Mounting Kit includes four 3 8 16 1 inch shoulder bol...

Страница 10: ...ne sealant or equivalent around and inside all conduit entries 12 Perform the initial programming of the telephone see the Programming section 13 Verify telephone operation by calling to and from anot...

Страница 11: ...or the type of bushing to be used 5 Pull the Ethernet cable through the bushing and install the cable see the Field Wiring section 6 Seal the cable entry point NOTE Use silicone sealant or equivalent...

Страница 12: ...Pub 42004 445L Rugged VoIP Handset Telephones Page 10 of 27 P Standard IOMs Current Release 42004 Instr Manuals 42004 445L docx 10 19 Figure 10 Model 246 700 Mounting Detail...

Страница 13: ...g holes in the rear enclosure 6 Drill a hole for the type of bushing to be used 7 Reinsert the hinge pins to attach the front half of the enclosure 8 Insert the Ethernet cable through the gland bushin...

Страница 14: ...Pub 42004 445L Rugged VoIP Handset Telephones Page 12 of 27 P Standard IOMs Current Release 42004 Instr Manuals 42004 445L docx 10 19 Figure 12 Model 256 700 Mounting Detail...

Страница 15: ...ts directly to the enclosure the back box is not required 3 Remove a tapered plug from one of the cable entry holes in the backbox 4 Install a cable fitting and pull the cabling into the backbox NOTE...

Страница 16: ...45L Rugged VoIP Handset Telephones Page 14 of 27 P Standard IOMs Current Release 42004 Instr Manuals 42004 445L docx 10 19 11 Torque the screws to 10 12 in lb 1 1 1 4 N m Figure 14 Model 276 700 Mount...

Страница 17: ...t cover 2 Remove the tapered plug s from the cable entry holes and feed all cabling into the dust cover see Figure 16 3 Terminate all wires see the Field Wiring section 4 Connect peripheral I O device...

Страница 18: ...dset Telephones Page 16 of 27 P Standard IOMs Current Release 42004 Instr Manuals 42004 445L docx 10 19 Figure 16 Models 276 702BH 702BHAC Dust Cover Detail Figure 17 Cutout and Framing Support Detail...

Страница 19: ...TE Use the six 10 32 security machine screws supplied with the surface mount enclosure along with the flat black washers included with the telephone Do not use the thread cutting screws supplied with...

Страница 20: ...system as indicated in your PoE equipment manual Local Power When PoE is not available a separate isolated 24 48 V dc power supply is required A removable terminal block P5 is provided for connection...

Страница 21: ...r 2 Secure the ground conductor to the ground terminal located in the rear of the front panel NOTE Not applicable to Models 246 700 and 256 700 Network Connect a Cat5 or Cat5E cable with an RJ45 conne...

Страница 22: ...tup 1 Connect a PC to the same network as the VoIP telephone 2 Log into the unit s web interface The unit is factory configured with a static IP address 192 168 1 2 3 Enter the user name and password...

Страница 23: ...Page Registered or Emergency In some modes the duration of the activation or on off times can also be set see Figure 18 and the logic settings section of GTC Pub 42004 481 VoIP Telephone Configuratio...

Страница 24: ...d prepaid to GAI Tronics with a return authorization number and a purchase order number Repairs or a replacement will be made in accordance with GAI Tronics warranty policy if the equipment is under w...

Страница 25: ...set Assembly with Armored Cord 12 inch 12512 001 Hookswitch Assembly Kit plastic 12512 002 Hookswitch Assembly Kit metallic 12512 012 Hookswitch Assembly Replacement 12513 006 Replacement Door Kit 125...

Страница 26: ...Pole Mounting Kit 22x Series 233 001 Model 233 001 Security Screwdriver 238 001 Surface Mount Enclosure Stainless Steel Standard 238 003 Surface Mount Enclosure Stainless Steel BH Telephones 12573 00...

Страница 27: ...158 F 40 C to 70 C Relative humidity up to 95 non condensing PCBA printed circuit board assembly conformal coated Models 210 700BH 700BHAC Enclosure Construction 16 guage 0 060 in type 304 stainless s...

Страница 28: ...ss steel Back Box 16 gauge 0 060 in steel with black polyurethane finish Handset cord G style with 29 inch armored cord and internal lanyard Braille dial pad chrome plated zinc Dimensions Front panel...

Страница 29: ...15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses an...

Страница 30: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: