Hubbell Compass CCE Скачать руководство пользователя страница 1

WARNING

 – This product contains chemicals known to the State of California to cause cancer, birth 

defects and/or other reproductive harm. Thoroughly wash hands after installing, handling, cleaning, 
or otherwise touching this product.

Thin  Die-Cast LED EXIT Sign

 CCE

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should 

always be followed including the following.

READ AND FOLLOW ALL SAFETY 

INSTRUCTIONS

 

1.  Do not use outdoors. 

  2.  Do not let power supply cords touch hot surfaces.
  3.  Do not mount near gas or electric heaters.
  4.  Equipment should be mounted in locations and at heights where it will not readily be subject 
   

to tampering by unauthorized personnel. 

  5.  The use of accessory equipment not authorized by the manufacturer may cause an unsafe condition.
  6.  Do not use this equipment for other than its intended purpose.
  7.  Servicing of this equipment should be performed by qualified service personnel.
  8.  Test cycling: the Life Safety Code (NFPA 101) requires testing of emergency lighting units once a month for a  
   

minimum of 30 seconds, and once a year for a minimum of 90 minutes.

 

INSTALLER: 

•SEE UNIT LABEL FOR ADDITIONAL MODEL SPECIFICATIONS

•SAVE THESE INSTRUCTIONS FOR USE BY OWNER/OCCUPANT

Parts Description (All parts provided unless noted otherwise)

Œ

  Face Plate



  Back Plate

Ž

  Mounting Hole Cover



  Red or Green Lens



 Canopy

‘

  Junction Box Screws (not shown)

’

  Wire Nuts

“

  Junction Box (not provided)

”

  Mounting Bracket

•

  Input WIres

NOTE: This fixture is for use only with 3 ½

"

 octagon, 4

"

 octagon, 4

"

 square or single-gang junction boxes, on an unswitched circuit. See Wiring 

Diagrams and “To Remove Directional Indicators” below before beginning fixture installation. On fixtures with battery: Connect battery only after 

continuous power can be supplied to the fixture. Allow 24 hours before initial test or for full charge.

Back Mounting (Single Face Units Only)

1.  Turn off AC power.

2.  Remove appropriate knockouts in backplate of EXIT sign enclosure. 

Knockouts are not intended for use with conduit fittings.

3.  Feed power supply module input wires from EXIT sign 

through the open knockout. Route wires along side walls of 

enclosure to assure proper sign illumination and to protect 

wires from damage.

4.  Connect building supply wires to the power supply module 

input wires and feed splices into the junction box. For 

120V supply connect the line wire to the black lead and for 

277V supply connect the line wire to the orange lead. Connect 

neutral wire to the white lead. The ground wire (green lead) must be 

connected in accordance with local codes. CAUTION: The unused black or orange wire must be capped 

with wire nut or other approved insulator. Failure to do so may cause an unsafe condition.

5.  Attach EXIT sign backplate to junction box with supplied screws.

6.  After AC power can be continuously supplied, push in connector from battery (if provided) to LED board.

7.  Snap EXIT faceplate into place on EXIT sign backplate.

8.  Turn on AC power.

INSTALLATION

Отзывы: