3
● Digital filter function, use the filter function to reduce the influence when the display
value is deviated due to external influence.
● Complete protection function, and equipped with fuse blowing prompt function.
● Data saving function, and data can be exported.
III.Technical specifications
● Safety specifications
IEC 61010-1 CAT.IV 600V Pollution degree 2
IEC 61326 EMC specification: electrical equipment for testing, control and inspection
IEC60529 IP64 (outer box closed state)
● AC power supply: 220V±10%, 50/60 HZ, 20 VA
● Battery power supply: 16.8V lithium ion battery
● Battery life time: 5000V@100M, about 6 hours
● Dimensions (length x width x height): 27cm x 23cm x 16cm
● Weight: 3.8kg
● Output voltage accuracy: 100% to 110% of the nominal value
● Output voltage monitoring accuracy: ±5%±10V
● Voltage measurement range: AC: 30-600V (50HZ/60HZ), DC: 30-600V
● Voltage measurement accuracy: ±2%±3dgt
● Current test range: 10mA
● Current measurement accuracy: 5%+0.2nA
● Short circuit current: 2 to 5mA, adjustable output
● Capacitance test range: 25uF
● Capacitance test accuracy: ±10%±0.03uF
● Discharge rate of capacitor sample: from 5000V to 10V, 1S/µF
● Protection: 2% error, shielding 500kΩ leakage resistance under 100MΩ load
● Analog display range: 100kΩ to 10TΩ
● Digital display range: 10kΩ to 20TΩ
● Insulation alarm: 0.01MΩ to 9999.99MΩ
● Insulation resistance test range and accuracy (temperature: 23±5ºC, relative
temperature: 45 – 75%RH)
Range
Accuracy
500V
1000V
2500V
5000V
10000V
Manual voltage
regulation
n.s.
<100K
<100K
<100K
<100K
<100K
Range: 1G/V, 100G at
100V. When the
voltage is less than
200V, the resistance
±5%rdg±3dgt
100K
-100G
100K-200G 100K-500G 100K-1T
100K-2T
±20%rdg
100G-1T 200G-2T 500G–5T
1T-10T
2T-20T