5

supply

3. I+, I-: are current output terminals, which provide constant current for the sample

through a dedicated test wire

4. V+, V-: input terminals for the voltage signal of the test product

5. Liquid crystal: using 320X240 true color liquid crystal, fonts can be clearly observed

under strong light, display operation settings, test results, contact resistance value and

output current value

6. RS232: serial port output

7. Reset key: the whole machine is initialized and the instrument is in the ready state

8. Selection key: Press this key to select various settings of the instrument, and the data

can be printed after measurement

9. Circulation key: main menu cycle selection key or U disk storage

10. Confirm key: Press the confirm key and the instrument will start the current for testing

11.: Ground terminal of the instrument.

12. USB: U disk interface

13. Printer: thermal printer, printing measurement results

V.Menu operation

1.The boot interface display is shown in Figure 1:

Figure 1

Press the cycle key and the cursor can move cyclically among current selection, host

parameter, time selection, and data query. When the cursor is in current selection, host

parameter, and data query, press the select key to enter the next menu of the selected

Содержание HZ-5300

Страница 1: ...HZ 5300 Contact Resistance Tester User Manual Huazheng Electric Manufacturing Baoding Co Ltd...

Страница 2: ...and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this instrum...

Страница 3: ...what will you notice before testing III Brief Introduction Working theory V Technical parameter VI PLC interface VII Operation Instructions and Procedures VIII Applying Illustration IX Calibration X...

Страница 4: ...artments Claim The output current and measuring resistance are simultaneously output on the 65K true color LCD and the measurement results can be voltage output or stored in a USB flash drive The powe...

Страница 5: ...lution min 0 1 Accuracy 0 5 2 words Power 1000W Working mode continuous measurement Power supply AC220V 10 50HZ Operating temperature 0 40 Relative humidity less than or equal to 90 without condensati...

Страница 6: ...Press this key to select various settings of the instrument and the data can be printed after measurement 9 Circulation key main menu cycle selection key or U disk storage 10 Confirm key Press the con...

Страница 7: ...ropriate measurement time and measurement current press the start button to start the current the screen displays charging a few seconds later it displays testing and a few seconds later it displays t...

Страница 8: ...to move the cursor to the clock to modify press the select key to enter the interface as shown in Figure 4 Figure 4 Press the cycle key to move the cursor between each date data press the select key...

Страница 9: ...uld be removed first 1 Wiring method As shown in Figure 6 connect the dedicated test wire to the corresponding I and I terminals according to the color red to red black to black and tighten the thin p...

Страница 10: ...sed to measure loop resistance and it is not allowed to measure inductive loops After sales service The instrument will be repaired and replaced free of charge for product quality problems within one...

Отзывы: