14
wire separate 150mm, they must install parallel with other cable. It better to use a separate cable chain
⑺
Install the HF box nearby the torch, the HF box need a separate earth cable to connect with the cutting table
⑻
Each parts, and other CNC or motor driver cover should have a separate earth cable to connect with cutting table,
include HF box
⑼
Connect the shield of torch conductive wire to the HF box and torch, it must insulate from the metal and ground.
⑽
If the cutting table not work along with the rail, it need cable to connect the rail terminal.
⑾
If need add voltage depressor for use in the CNC system, it should install nearby the voltage sample place. Inside the
plasma machine is suitable, the signal should within the insulation cable, which should have cloth shield but not
aluminium shield. The shield should connect to the cutting machine basement, and other side not connect.
⑿
Other signal(analogy, digital, parallel, encoder)should in the insulation cable, the connector of these cable should have
cover or shield.
6. Installation drawing
Note:
⑴
Check all the parts before install the cable and hose
⑵
Ground connect well for all parts
⑶
To avoid any gas or coolant leak, connect all the gas and water hose with following way
Cable and hose fix
Содержание SLG-200HF
Страница 1: ...SLG 200 300 400HF PLASMA CUTTING MACHINE MANUAL INSTRUCTION PLEASE READ IT CAREFULLY BEFORE OPERATION...
Страница 12: ...5 3 2 SLG 300HF dimension and weight 3 3 SLG 400HF dimension and weight...
Страница 22: ...15 5 2 Installation Drawing System components A Plasma power sourceSLG 200HF 300HF 400HF...
Страница 47: ...40 3 Circuit diagram 7 1 SLG 200HF...
Страница 48: ...41 7 2 SLG 300HF...
Страница 49: ...42 7 3 SLG 400HF...
Страница 50: ...43 7 4 QFK E1...