Figure 12-5 Connecting a cable to the management network port of a server
node
Step 3 Set the IP address of the PC.
Set the IP address, subnet mask, or route of the PC and ensure that the PC can
communicate with the iBMC management network port.
Run the Ping
iBMC management network port IP address
command on the PC CLI
to check whether the PC can properly communicate with the server.
Step 4 Enable the port aggregation function for the server node.
●
Enable network port aggregation by using the iBMC WebUI or CLI.
–
Method 1: Enable network port aggregation on the iBMC WebUI.
i.
Log in to the iBMC WebUI, select Fixed as the network port mode on
the NetWork Settings page, and select a network port under
Aggregation Port. See
.
TaiShan X6000 Server
User Guide
12 Common Operations
Issue 04 (2020-06-05)
Copyright © Huawei Technologies Co., Ltd.
86