Huawei UPS5000-S-105K Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

UPS5000-S-(35 kVA-210 kVA)

 

 

User Manual (Singapore, 35 kVA 
Power Modules)

 

 

 

Issue 

02

 

Date 

2020-01-10

 

HUAWEI TECHNOLOGIES CO., LTD. 

Содержание UPS5000-S-105K

Страница 1: ...UPS5000 S 35 kVA 210 kVA User Manual Singapore 35 kVA Power Modules Issue 02 Date 2020 01 10 HUAWEI TECHNOLOGIES CO LTD ...

Страница 2: ...tomer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to c...

Страница 3: ...ioning engineers Data configuration engineers Maintenance engineers Symbol Conventions The symbols that may be found in this document are defined as follows Symbol Description Indicates a hazard with a high level of risk which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a...

Страница 4: ...information not related to personal injury equipment damage and environment deterioration Change History Changes between document issues are cumulative The latest document issue contains all the changes made in earlier issues Issue 02 2020 01 10 Added SNMP descriptions to the sections about site configuration Added the SNMP V1 and V2 protocol description Updated the safety information Issue 01 201...

Страница 5: ... Battery Safety 11 1 8 Others 14 2 Overview 15 2 1 Model Description 15 2 2 Working Principle 15 2 2 1 Conceptual Diagram 16 2 2 2 Working Modes 16 2 2 2 1 Normal Mode 16 2 2 2 2 Bypass Mode 17 2 2 2 3 Battery Mode 18 2 2 2 4 Joint Power Mode 19 2 2 2 5 Maintenance Bypass Mode 20 2 2 2 6 ECO Mode 21 2 3 Product Introduction 23 2 3 1 Product Structure 23 2 3 2 Power Module 25 2 3 3 Bypass Module 27...

Страница 6: ... 7 3 UPS Cable Connection Reference 58 3 7 4 Routing Cables 59 3 7 5 Installing Optional Components 65 3 7 5 1 Connecting an Ambient T H Sensor 65 3 7 5 2 Installing a Battery Grounding Failure Detector 66 3 7 5 3 Connecting a BMU 66 3 7 6 Remote EPO 67 3 8 Installing a Parallel System 68 3 8 1 Mechanical Installation 68 3 8 2 Routing Cables 69 3 9 Installation Verification 73 4 User Interface 77 ...

Страница 7: ...d Message Sending 137 4 2 6 3 UPS Alive Check Function 138 5 Operations 141 5 1 Powering On and Starting the UPS 141 5 1 1 Powering On the UPS 141 5 1 2 Starting the Inverter 141 5 1 2 1 Initial Startup 142 5 1 2 2 Non initial Startup 148 5 1 3 Powering On Loads 150 5 1 4 Optional Setting Parameters for the BCB Box 150 5 2 Shutting Down and Powering Off the UPS 151 5 3 Starting the UPS in Battery ...

Страница 8: ...6 1 2 Quarterly Maintenance 167 6 1 3 Annual Maintenance 167 6 2 Battery Maintenance 168 6 2 1 Precautions for Battery Maintenance 169 6 2 2 Monthly Maintenance 169 6 2 3 Quarterly Maintenance 170 6 2 4 Annual Maintenance 171 7 Troubleshooting 172 8 Technical Specifications 174 A Short circuiting the Input N and PE 179 B Menu Hierarchy 180 B 1 Menus on the LCD 180 B 2 Menus on the WebUI 182 C Alar...

Страница 9: ...ng operating or maintaining the equipment The safety instructions in this document are only supplements to local laws and regulations Huawei will not be liable for any consequences of the following circumstances Operation beyond the conditions specified in this document Installation or use in environments which are not specified in relevant international or national standards Unauthorized modifica...

Страница 10: ...a conductor surface or terminal measure the contact point voltage and ensure that there is no risk of electric shock After installing the equipment remove idle packing materials such as cartons foam plastics and cable ties from the equipment area In the case of a fire immediately leave the building or the equipment area and turn on the fire alarm bell or make an emergency call Do not enter the bui...

Страница 11: ... with scratches cannot be exposed to an outdoor environment for a long period of time Before operations ensure that the equipment is firmly secured to the floor or other solid objects such as a wall or an installation rack Do not use water to clean electrical components inside or outside of a cabinet Do not change the structure or installation sequence of equipment without permission Do not touch ...

Страница 12: ...d are clear of the sources and degree of various potential hazards in equipment installation operation maintenance Trained personnel personnel who are technically trained have required experience are aware of possible hazards on themselves in certain operations and are able to take protective measures to minimize the hazards on themselves and other people Operators operation personnel who may come...

Страница 13: ... cables ensure that a distance of at least 30 mm exists between the cables and heat generating components or areas This prevents damage to the insulation layer of the cables Do not route cables behind the air intake and exhaust vents of the equipment Ensure that cables meet the VW 1 flame spread rating requirements Bind cables of the same type together When routing cables of different types ensure...

Страница 14: ...ironment Requirements To prevent fire due to high temperature ensure that the ventilation vents or heat dissipation system are not blocked when the equipment is running Install the equipment in an area far away from liquids Do not install it under areas prone to condensation such as under water pipes and air exhaust vents or areas prone to water leakage such as air conditioner vents ventilation ve...

Страница 15: ...rn away irrelevant personnel Carry the operation machinery and tools properly to prevent them from falling off and causing injuries Personnel involving working at heights are not allowed to throw objects from the height to the ground or vice versa Objects should be transported by tough slings hanging baskets highline trolleys or cranes Ensure that guard rails and warning signs are set at the edges...

Страница 16: ...t it is intact and confirm its load bearing capacity Do not overload it Ensure that the ladder is securely positioned The recommended angle for a ladder against the floor is 75 degrees as shown in the following figure An angle rule can be used to measure the angle Ensure that the wider end of the ladder is at the bottom or protective measures have been taken at the bottom to prevent the ladder fro...

Страница 17: ...aware of unstable or heavy objects on the cabinet Be cautious to avoid injury when moving heavy objects When moving the equipment by hand wear protective gloves to prevent injuries Move or lift the equipment by holding its handles or lower edges Do not hold the handles of modules such as power supply units fans and boards that are installed in the equipment because they cannot support the weight o...

Страница 18: ...on as possible If you temporarily do not use the UPS take appropriate measures to prevent moisture dust and foreign matter from entering the UPS After unpacking batteries you are advised to connect the battery supply as soon as possible If you temporarily do not use the batteries store them in a dry and clean environment If batteries are stored for more than 90 days charge them in time Otherwise t...

Страница 19: ...or semi indoor environments where the temperature and humidity are not controllable such as simple equipment rooms civil houses garages corridors and direct ventilation cabinets near the sea or houses with only roofs railway station platforms gymnasiums and aquariums Environments that are conducive for the growth of microorganisms such as fungus or mildew Environments where rodents such as mice an...

Страница 20: ...ies not provided by Huawei Battery Installation Before installing batteries observe the following safety precautions Install batteries in a well ventilated dry and cool environment that is far away from heat sources flammable materials moistures extensive infrared radiation organic solvents and corrosive gases Take fire prevention measures Place and secure batteries horizontally Note the polaritie...

Страница 21: ...age the equipment It will corrode metal parts and boards and ultimately damage the boards If the electrolyte overflows follow the instructions of the battery manufacturer or neutralize the electrolyte by using sodium bicarbonate NaHCO3 or sodium carbonate Na2CO3 Lithium Battery The safety precautions for lithium batteries are similar to those for lead acid batteries except that you also need to no...

Страница 22: ...sed Do not throw a lithium battery in fire When maintenance is complete return the waste lithium battery to the maintenance office 1 8 Others Exercise caution when manually shutting down the UPS inverter for transferring to bypass mode or when adjusting the UPS output voltage level or frequency Doing so may affect the power supply to equipment Exercise caution when setting battery parameters Incor...

Страница 23: ...1 UPS model number description Iden tifier Meaning Value 1 Product category UPS short for uninterruptible power system 2 UPS family 5000 3 UPS subcategory S series 4 Output capacity 210K 210 kVA 5 Configuration type SM standard configuration 6 Protection level IP42 This model includes the following configurations 35 kVA 70 kVA 105 kVA 140 kVA 175 kVA and 210 kVA 2 2 Working Principle indicates an ...

Страница 24: ...0 adopts intelligent control Its power module consists of a rectifier inverter and DC DC converter The UPS5000 converts inputs into pure high quality sine wave outputs by using the high frequency switching technology Figure 2 2 UPS conceptual diagram 2 2 2 Working Modes 2 2 2 1 Normal Mode In normal mode the rectifier converts AC power into DC power then the inverter converts DC power into high pr...

Страница 25: ...UPS conceptual diagram in normal mode 2 2 2 2 Bypass Mode The UPS automatically transfers to bypass mode upon detecting power module overtemperature overload or other faults that may cause the inverter to shut down The bypass power supply is not protected by the UPS which means it may be affected by mains outage and incorrect AC voltage or frequency ...

Страница 26: ...ht Huawei Technologies Co Ltd 18 Figure 2 4 UPS conceptual diagram in bypass mode 2 2 2 3 Battery Mode If the mains input is abnormal or the rectifier becomes abnormal the UPS transfers to battery mode The power module obtains DC power from batteries and the power is converted into AC output by the inverter ...

Страница 27: ...9 Figure 2 5 UPS conceptual diagram in battery mode 2 2 2 4 Joint Power Mode If the UPS works properly and the AC input power of the rectifiers is insufficient the UPS transfers to joint power mode In this case the power module obtains energy from both the mains and batteries and the energy is converted into AC outputs over the inverter ...

Страница 28: ... 10 Copyright Huawei Technologies Co Ltd 20 Figure 2 6 Conceptual diagram in joint power mode 2 2 2 5 Maintenance Bypass Mode When the UPS works in maintenance bypass mode the current flows through the maintenance bypass instead of the power module You can maintain the circuit inside the cabinet ...

Страница 29: ... can be configured on the LCD or web user interface WebUI In ECO mode when the bypass input is within the ECO voltage and frequency ranges and other ECO power supply conditions are met the UPS works in bypass mode and the inverter is in standby state When the bypass voltage is outside the ECO voltage range the UPS transfers from bypass mode to normal mode In bypass mode or normal mode the rectifie...

Страница 30: ...VA Power Modules 2 Overview Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 22 Figure 2 8 UPS conceptual diagram in ECO mode Manual startup is required to ensure that the inverter is in standby state and the power flow has reached the inverter ...

Страница 31: ...000 S 35 kVA 210 kVA User Manual Singapore 35 kVA Power Modules 2 Overview Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 23 2 3 Product Introduction 2 3 1 Product Structure Figure 2 9 Appearance ...

Страница 32: ...les 2 Overview Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 24 Figure 2 10 Structure with the door open 1 Power modules 2 Bypass module 3 Control module 4 Power distribution subrack cover 5 Monitor display unit 6 Filler panels 7 Maintenance bypass switch ...

Страница 33: ...ort Table 2 2 Indicator description Indicator Color Status Description Run indicator Green Steady on The system is working in inverter mode Blinking at long intervals The inverter is ready and in standby state blinking at 0 5 Hz on for 1s and off for 1s The inverter is not started blinking at 0 2 Hz on for 2 5s and off for 2 5s Blinking at short intervals The module is not configured the inverter ...

Страница 34: ... CPLD software is being upgraded Fault indicator Red Steady on A critical alarm is generated for the inverter or rectifier Off There is no critical alarm for the inverter or rectifier or the rectifier CPLD software is being upgraded Functions The power module consists of a power factor correction PFC rectifier inverter and DC DC converter The power module performs AC DC or DC DC conversion on the ...

Страница 35: ...rm indicator 5 Fault indicator 6 Ready switch 7 Signal port 8 Input and output ports 9 Crowbar Table 2 3 Indicator description Indicator Color Status Description Run indicator Green Steady on The system is working in bypass mode Blinking at long intervals The bypass has no output blinking at 0 2 Hz on for 2 5s and off for 2 5s Blinking at short intervals The bypass is not configured or the DSP sof...

Страница 36: ... the following cases If the UPS is set to ECO mode and the bypass voltage is within the specified range the UPS works in bypass mode If the power module overload times out the UPS transfers to bypass mode Both the active and standby ECMs are abnormal The system fails to run properly and transfers to bypass mode A manual operation is performed to transfer to bypass mode Specifications Dimensions H ...

Страница 37: ...11 Dry contacts 12 MDU port 13 RS485 port 14 Fast Ethernet FE port 15 COM2 port 16 COM1 port 17 Battery temperature sensor port 18 Optional card subrack cover Ports are protected by a security mechanism 2 3 4 2 ECM Appearance The control module consists of two energy control modules ECMs in active standby mode Figure 2 14 ECM Table 2 4 Ports on the ECM Silk Screen Description PARALLEL The PARALLEL...

Страница 38: ...r alarm but it does not need to be replaced Off The ECM has no minor alarm or the DSP of the ECM is being upgraded FAULT Red Steady on The ECM has a critical alarm Off The ECM has no critical alarm or the DSP of the ECM is being upgraded Functions As a control interface for the entire system the ECM communicates with each module and provides a bus to communicate with the dry contact card The ECM e...

Страница 39: ...3 Dry contact card Appearance Figure 2 16 Dry contact card Table 2 6 Ports on the dry contact card Silk Screen Description Status Initial Status BTG Port for detecting battery grounding faults Connected battery grounding fault Disconnected no battery grounding fault Disconnected 0V Port for signal ground GEN Port for detecting diesel generator D G mode Connected D G mode Disconnected non D G mode ...

Страница 40: ...to the EPO_12V port EPO is triggered Disconnected EPO_12V 12 V EPO_NC EPO port If the normally closed NC port is disconnected from the EPO_12V port EPO is triggered Connected EPO_12V 12 V SWITCH STATUS_OUT Port for monitoring the UPS output circuit breaker Connected circuit breaker ON Disconnected circuit breaker OFF Connected SWITCH STATUS_0V Port for signal ground SWITCH STATUS_MT Port for monit...

Страница 41: ...when connecting communications cables as if the RS485 port is mistaken for the FE port during cable connection the WebUI cannot be connected Conversely if the FE port is mistaken for the RS485 port during cable connection RS485 communication fails If MDU communication fails the Comm failure message is displayed on the LCD screen switching is disabled the buzzer buzzes and the fault indicator is re...

Страница 42: ...ndicates minor alarms by default It can be set to indicate critical alarms bypass mode battery mode or low battery voltage COM DO_3 NO DO_3 is used to output alarms and indicates bypass mode by default It can be set to indicate critical alarms minor alarms battery mode or low battery voltage COM DO_4 NO DO_4 is used to output alarms and indicates battery mode by default It can be set to indicate c...

Страница 43: ...S485 Connects to a northbound network management device or a third party network management device over two wires Signal cables must be double insulated twisted cables If the cable length is 25 50 m the cross sectional area must be 0 5 1 5 mm2 RS485 cables and FE cables must be shielded cables Figure 2 18 and Figure 2 19 are recommended wiring methods for DO ports Figure 2 18 Wiring method 1 Figur...

Страница 44: ...s 2 Overview Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 36 Figure 2 20 COM1 pins Table 2 8 COM1 pin definition Pin Description 1 GND 2 N A 3 RS485 4 RS485 5 N A 6 12V_PORT Figure 2 21 and Table 2 9 describe the COM2 pin definitions Figure 2 21 COM2 pins ...

Страница 45: ...echnologies Co Ltd 37 Table 2 9 COM2 pin definition Pin Description 1 RS485 2 RS485 3 N A 4 RS485 5 RS485 6 GND 7 CANH0 8 CANL0 Figure 2 22 and Table 2 10 describe the RS485 pin definitions Figure 2 22 RS485 pins Table 2 10 RS485 pin definition Pin Description 1 RS485_T 2 RS485_T 3 N A 4 RS485_R 5 RS485_R 6 GND 7 N A ...

Страница 46: ...st cables to pin 1 and pin 4 into one cable and then connect it to RS485 Twist cables to pin 2 and pin 5 into one cable and then connect it to RS485 2 3 5 MDU Appearance Figure 2 23 MDU 1 Status indicator 2 LCD touchscreen Table 2 11 Status indicator Status Color Meaning On Red A critical alarm has been generated and the buzzer sounds continuously Yellow A minor alarm has been generated and the bu...

Страница 47: ...ment View or obtain UPS running information during preventive maintenance NOTE Only Huawei service engineers or authorized service engineers are allowed to use the WiFi module To ensure security remove the WiFi module immediately after use Insert the USB flash drive import and export the configuration file export run logs and upgrade software 6 RST Restart switch for the MDU 7 SD Reserved 8 DIP sw...

Страница 48: ...m advantages the dual bus system also provides outstanding availability and eliminates bottleneck failures However configuration of the dual bus system is complex A 1 1 parallel system is a typical configuration You can set the number of requisite UPSs and redundant ones on the LCD or WebUI 2 4 1 Single UPS This series uses a modular design in which multiple power modules are connected in parallel...

Страница 49: ...wo independent UPS systems Each of these UPS systems in turn consists of one or more UPSs connected in parallel Of the two UPS systems one is a master system and the other is a slave system This design makes the dual bus system highly reliable and suitable for loads with multiple input terminals An optional static transfer switch STS can be installed to start the bus synchronization controller BSC...

Страница 50: ...1 PDU8000 0250DCV8 BXA001 PDU8000 0400DCV8 BXA001 PDU8000 0630DCV8 BXA001 PDU8000 0800DCV8 BXA001 Controls the connection between battery strings and the UPS and supports overload protection short circuit protection and remote trip control PDU8000 0125 0250 0400 0630 0800 DCV8 BXA001 BCB Box User Manual Battery bus bar BBB box PDU8000 0630DCV8 BGA001 PDU8000 1250DCV8 BGA001 PDU8000 Converges the e...

Страница 51: ... When equipped with a remote trip switch the detector protects devices and prevents fire outbreak Detects battery grounding failures and generates alarms when the ground leakage current exceeds the specified value UPS Battery Grounding Failure Detector User Manual Ambient temperature and humidity sensor N A Monitors the ambient temperature and humidity and can be applied to batteries UPS Ambient T...

Страница 52: ...35 kVA Power Modules 3 Installation Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 44 3 Installation 3 1 Dimensions Figure 3 1 Dimensions unit mm 1 Front door 2 Foot 3 Caster 4 Base 5 Rear panel 6 Base installation hole 7 Beam 8 Side beam ...

Страница 53: ... conductive metal scraps in the air The optimal operating temperatures for valve regulated lead acid batteries VRLA batteries are 20 30 C Operating temperatures higher than 30 C shorten the battery lifespan and operating temperatures lower than 20 C reduce the battery backup time 3 3 Installation Clearances Reserve the following clearances around the cabinet to facilitate operations and ventilatio...

Страница 54: ...ng tools and meters indicated in Table 3 1 for installation Table 3 1 Tools and meters Tools and Meters Electric pallet truck Manual pallet truck Ladder Rubber mallet Hammer drill and drill bit Φ16 Hand held electric drill Alloy hole saw Heat gun Diagonal pliers Crimping tools Wire stripper Electric hydraulic pliers Clamp meter Multimeter Cable tie Level instrument Polyvinyl chloride PVC insulatio...

Страница 55: ...le wrench Table 3 1 lists only the common tools for installation and cable connection For more dedicated tools required see the corresponding component manuals Prepare tools based on site requirements 3 5 Preparing Power Cables The UPS can generate large leakage currents A circuit breaker that provides leakage current protection is not recommended If multiple UPSs are to be connected in parallel i...

Страница 56: ...ea mm2 L1 4x25 4x50 4x95 4x120 4x150 2x 4x95 L2 L3 N PE 25 25 50 70 70 95 Output Output current A 54 107 160 213 266 320 Recommended cross sectional area mm2 U 4x25 4x25 4x50 4x95 4x120 4x150 V W N PE 25 25 25 50 70 70 Batter y input Battery nominal discharge current A 81 162 243 324 404 485 Battery maximum discharge current A 93 185 278 370 462 555 Recommended cross sectional area mm2 2x25 2x35 2...

Страница 57: ...wer cables In addition cables listed in Table 3 2 apply only to the following conditions 90 C flexible copper power cable Multi core cables are recommended for mains and bypass input and output power cables and single core cables are recommended for battery cables Routing mode Mains and bypass input and output power cables are routed over a ladder or bracket E in IEC60364 5 52 and battery cables a...

Страница 58: ...uit breaker 250 A 3P 200 140 kVA Mains input circuit breaker 400 A 3P 360 Bypass input circuit breaker 320 A 3P 288 Downstream output circuit breaker 320 A 3P 288 175 kVA Mains input circuit breaker 630 A 3P 441 Bypass input circuit breaker 400 A 3P 360 Downstream output circuit breaker 400 A 3P 360 210 kVA Mains input circuit breaker 630 A 3P 504 Bypass input circuit breaker 400 A 3P 400 Downstre...

Страница 59: ...ter placing the UPS in the installation position unpack it and take care to prevent scratches Keep the UPS steady during unpacking To prevent dust from settling on the UPS leave the original plastic coat on until installation is required Procedure Step 1 Use a pallet truck to transport the UPS to the installation position Step 2 Check the UPS packing Step 3 Hold the sliding plate steady Cut and re...

Страница 60: ...pect the UPS appearance for shipping damage If it is damaged notify the carrier immediately 2 Check that all fittings comply with the packing list If some fittings are missing or do not comply with the packing list record this information and contact your local Huawei office immediately Step 7 Remove the L shaped bracket that secures the cabinet and the pallet and secure the sliding plate to the p...

Страница 61: ...e plate may move when the UPS is removed Step 8 Raise the four anchor bolts to the highest position using an adjustable wrench Figure 3 6 Raising anchor bolts Step 9 Push the cabinet along the sliding plate to the floor End 3 7 Installing a Single UPS 3 7 1 Installing the UPS Cabinet Floor Installation Step 1 Determine the cabinet installation position on the floor based on the securing holes of t...

Страница 62: ... drill to drill holes for installing the expansion bolts and then install the expansion sleeves in the holes Figure 3 8 Expansion bolt composition 1 M12 bolt 2 Spring washer 3 Flat washer 4 Expansion sleeve Ensure the expansion tube of the expansion bolts fits completely into the hole The expansion sleeves must be completely buried under the ground to properly facilitate subsequent installation ...

Страница 63: ...t using a rubber mallet until the expansion sleeve is fully inserted into the hole 3 Partially tighten the expansion bolt 4 Remove the bolt spring washer and flat washer Step 3 Wheel the cabinet to the installation position Step 4 Adjust the four anchor bolts at the bottom of the UPS cabinet until all the four castors at the bottom hang in the air and the anchor bolts bear all of the cabinet weigh...

Страница 64: ...lation Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 56 Figure 3 10 Removing rubber plugs Step 7 Insert four M12x115 expansion bolts into the expansion bolt holes in the floor and tighten the expansion bolts Figure 3 11 Tightening bolts End Channel Steel Installation ...

Страница 65: ... steels based on the securing holes of the cabinet Step 2 Drill mounting holes on the channel steels using a hammer drill Step 3 Adjust the four anchor bolts at the bottom of the UPS cabinet until all the four castors at the bottom hang in the air and the anchor bolts bear all of the cabinet weight Step 4 Use a pallet truck to move the cabinet to the installation position Step 5 Remove the rear co...

Страница 66: ... with batteries End 3 7 3 UPS Cable Connection Reference Context Keep away from cabinets when preparing cables to prevent cable scraps from entering the cabinets Cable scraps may cause ignition during power on and result in personal injury and device damage After installing cables clean the cabinet top bottom copper bar wiring positions and other positions Ensure that there is no dust or scraps in...

Страница 67: ...ppropriate cabling route based on the actual situation The figure is for reference only Step 4 Connect the cable with a crimped terminal to the corresponding copper bar Step 5 Clean foreign matter inside the cabinet End 3 7 4 Routing Cables Context When connecting battery cables you do not need to connect neutral wires Procedure Step 1 Open the front door and remove the cover from the power distri...

Страница 68: ...r Figure 3 15 Removing the cover 1 Battery input terminals 2 Bypass input terminals 2L1 2L3 N 3 Mains input terminals 1L1 1L3 N 4 Output terminals U V W and N 5 Maintenance bypass switch Step 2 Determine the cabling mode Remove small covers for routing cables Take out the cable tray cover for signal cables and remove small covers from the bottom based on site requirements ...

Страница 69: ... 3 16 Removing small covers from the bottom of the cabinet Drill holes into the large cover for routing cables a Remove all small covers from the bottom of the cabinet b Remove the two large covers from the rear bottom of the cabinet drill holes into them and install them to the positions where the small covers were placed Figure 3 17 Hole positions ...

Страница 70: ...in the above figure is for reference only If holes are drilled for routing cables attach grommet strips to the hole edges to protect cables c Reinstall the removed two small covers on the holes at the rear bottom of the cabinet Figure 3 18 Installing small covers Step 3 Connect ground cables Figure 3 19 Grounding Internal equipotential connection Protection ground ...

Страница 71: ...allation Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 63 Step 4 Route power cables Dual mains Remove the copper bars between mains and bypass input terminals Figure 3 20 Removing copper bars Figure 3 21 shows the power cables routed from the bottom of the cabinet ...

Страница 72: ...or single mains the copper bars between the mains and bypass input terminals do not need to be removed and bypass input cables do not need to be connected Step 5 Route the signal cables on the left side of subracks along the left side of the cabinet and the cables on the right side of subracks along the right side of the cabinet and then bind the cables to the cabinet as shown in Figure 3 22 ...

Страница 73: ...2 Connecting signal cables The number and colors of signal cables in Figure 3 22 are for reference only End 3 7 5 Installing Optional Components 3 7 5 1 Connecting an Ambient T H Sensor Procedure Step 1 Connect the RJ11 port on the ambient T H sensor to the COM1 port on the monitoring interface card Figure 3 23 Connecting a UPS and an ambient T H sensor ...

Страница 74: ...sed as a battery temperature sensor End 3 7 5 2 Installing a Battery Grounding Failure Detector Procedure Step 1 Install a battery grounding failure detector Figure 3 24 Position of a battery grounding failure detector in the UPS 1 Battery grounding failure detector End 3 7 5 3 Connecting a BMU Procedure Step 1 Connect a BMU to the COM2 port on the monitoring interface card ...

Страница 75: ...is 22 AWG Equip the EPO switch with a protective cover to prevent misoperations and cover the cable with protective tubing Triggering EPO will shut down the rectifier inverter charger and static bypass but does not disconnect the UPS mains input To power off the UPS completely open the front end input switch when triggering EPO Connect the requisite EPO switch to UPS dry contacts Figure 3 26 shows...

Страница 76: ... NC state remove the jumper between EPO_NC and EPO_12V before connection When the EPO switch is turned off EPO is triggered When the EPO switch is in the NO state ensure that the jumper is connected between EPO_NC and EPO_12V When the EPO switch is turned on EPO is triggered 3 8 Installing a Parallel System 3 8 1 Mechanical Installation Procedure Step 1 Install the UPSs in a parallel system using ...

Страница 77: ...3 28 Installing connecting kits End 3 8 2 Routing Cables Procedure Step 1 Ground each UPS in a parallel system separately and connect power cables and battery cables Step 2 Select a parallel connection method to connect cables for the parallel system based on the site configurations The typical scenario of a 1 1 parallel system is used as an example ...

Страница 78: ... Copyright Huawei Technologies Co Ltd 70 Figure 3 29 Conceptual diagram of a 1 1 parallel system Figure 3 30 Cable connections for a 1 1 parallel system 1 Battery cables 2 Bypass input power cables 3 Mains input power cables 4 Output power cables The two subsystems of a bus system are used as an example ...

Страница 79: ...Technologies Co Ltd 71 Figure 3 31 Conceptual diagram of a dual bus parallel system Figure 3 32 Cable connections for a dual bus parallel system 1 Battery cables 2 Bypass input power cables 3 Mains input power cables 4 Output power cables Step 3 Connect the parallel ports on the UPSs using parallel cables to form a loop ...

Страница 80: ...n Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 72 1 1 parallel system Figure 3 33 Topology for a 1 1 parallel system Figure 3 34 shows only control modules Each control module represents a single UPS Figure 3 34 Parallel signal cable connections Dual bus parallel system ...

Страница 81: ... each UPS End 3 9 Installation Verification Table 3 5 lists check items If the check results of listed items 8 and 9 in Table 3 5 do not meet the acceptance criteria the UPS may be damaged Table 3 5 Installation checklist No Item Acceptance Criteria 01 UPS installation The UPS is securely installed and does not tilt due to vibration 02 Neat arrangement The UPS and its adjacent cabinets are neatly ...

Страница 82: ...the UPS ground bar and the equipment room ground bar is less than 0 1 ohm 08 AC phase sequence For a single UPS the mains input bypass input and output phase sequences are correct For a parallel system the phase sequences of each UPS must be consistent 09 Battery cable connections The battery strings are correctly connected to the UPS 10 Foreign matter cleaning inside the cabinet The inside and ou...

Страница 83: ... are removed for routing cables after routing cables and checking cable connections use sealing putty to fill in the gap between the cables and the cabinet 2 After verifying the installation reinstall all the covers 3 Do not remove the dustproof cover before power on to prevent dust inside the UPS Figure 3 36 Positions for checking foreign matter 1 Cabinet top 2 Wiring terminal blocks 3 Switches 4...

Страница 84: ...er Manual Singapore 35 kVA Power Modules 3 Installation Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 76 Figure 3 37 Fill the holes with sealing putty 1 Paper protective film 2 Sealing putty Figure 3 38 Dustproof cover ...

Страница 85: ...20 01 10 Copyright Huawei Technologies Co Ltd 77 4 User Interface 4 1 LCD Interface 4 1 1 Menu Hierarchy Figure 4 1 shows the LCD menu hierarchy Figure 4 1 Menu hierarchy 4 1 2 Main Menu User interfaces displayed in this document correspond to the MDU version V300R002C02 and are for reference only ...

Страница 86: ...on current date and time USB flash drive status and buzzer status 2 Alarm bar Displays active alarms in a scrolling list and the number of active alarms based on severity Tap the alarm icon area to open the active alarm page 3 Informatio n area Displays the power flow as well as key information such as load and battery information Tap the Bypass Mains Battery and Load icons to view details Table 4...

Страница 87: ...fault User Preset Password admin administrator 000001 operator common user 000001 4 1 3 System Info Figure 4 3 System info 4 1 3 1 Module Data On the System Info tap the UPS picture On the Module Data screen select a module to view its running data indicates the selected module Figure 4 4 Module data 4 1 3 2 Running On the System Info screen tap to access the Runn Info screen ...

Страница 88: ...ed on the Runn Info screen Choose Monitoring Param Settings Output Setting on the WebUI if the Current equal detection is set to Enable and the number of inverter modules is greater than or equal to 2 the Mod Cur Eql Data is displayed on the Runn Info screen Table 4 4 AC output Item Description Phase voltage V AC output phase voltage Line voltage V AC output line voltage Phase current A AC output ...

Страница 89: ...tor Proportion of the peak value of load current to the valid value Hist Max Load Ratio Historical maximum load ratio of each phase on the UPS Hist Max Active Power kW Historical maximum active power of each phase on the UPS Hist Max Apparent Power kVA Historical maximum apparent power of each phase on the UPS Table 4 6 Mains input Item Description Phase voltage V Mains input phase voltage Line vo...

Страница 90: ...is displayed Backup time min Battery backup time estimated at the current load Remaining cap Remaining battery capacity SOH State of health Table 4 9 Total runtime Item Description Bypass runtime h Time for which the UPS runs in bypass mode Inv runtime h Time for which the UPS runs in inverter mode The value must be an integer For example If the value is less than 1 the value takes 0 If the value ...

Страница 91: ...rrent SOC and SOH data of each battery string Battery Detailed Data String N Battery Data reflects the temperature voltage internal resistance current SOC and SOH data of a single battery in the battery string 4 1 3 3 Alarms Screen Tap on the System Info screen to enter the Alarms screen Figure 4 7 Alarms Screen Active alarms This screen displays alarm information including the severity name ID lo...

Страница 92: ...ime and clear time Figure 4 9 Historical alarms Buzzer Off Two buzzer menus are available Buzzer On If this selection is enabled when a critical alarm a minor alarm or a certain warning is generated the buzzer is activated Buzzer Off If this selection is enabled the buzzer is muted If the buzzer is enabled Buzzer Off is displayed on the operation screen 4 1 3 4 Settings On the System Info screen t...

Страница 93: ...anual Singapore 35 kVA Power Modules 4 User Interface Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 85 Figure 4 11 Settings 2 Communication Settings Figure 4 12 Communication settings 1 Figure 4 13 Communication settings 2 ...

Страница 94: ...ess and the PC IP address with the subnet mask respectively If the operation results are the same the two IP addresses are in the same subnet AND operation rule 1 AND 1 1 1 AND 0 0 0 AND 1 0 0 AND 0 0 That is when the corresponding bits are both 1 the result is 1 In other cases the result is 0 Table 4 11 BitwiseAND operation example PC IP address 182 98 225 125 UPS IP address 182 98 225 112 PC IP ...

Страница 95: ...55 Gateway Specifies the Ethernet gateway 192 168 0 1 1 0 0 0 223 255 255 255 MAC address Defines the physical address of network equipment and is not configurable NAT mapping NAT means network address translation If it is set to Disable Internet cannot access IP addresses in the local area network LAN Disable Disable Enable Figure 4 15 RS485 communication settings Item Description Default Value V...

Страница 96: ...ode Stop bit Stop bit in the Modbus communication frame format When the UPS is connected over the serial port Modbus set this parameter based on the frame format that the upstream device Modbus supports 1 1 2 Figure 4 16 Modbus TCPsettings Item Description Default Value Value Range ModbusTCP encryption If Modbus TCP is used for communication communication links do not implement encryption or imple...

Страница 97: ... 4 17 Ambient temperature and humidity sensor Item Description Default Value Value Range Start address 32 32 44 Quantity Number of cascaded ambient temperature and humidity sensors 0 0 4 Figure 4 18 Battery temperature sensor Item Description Default Value Value Range Start address 16 16 28 Quantity Number of cascaded battery temperature sensors 0 0 4 ...

Страница 98: ...ess 112 Quantity Number of cascaded BMUs 0 0 12 Figure 4 20 WiFi communication settings Item Description Default Value Value Range SSID When using the mobile app for site setup or inspection set WiFi SSID after connecting a WiFi module over a USB port to identify the WiFi device to which the mobile phone is connected UPS_WIFI Last six characters of the MAC address Password The password for accessi...

Страница 99: ...lue Range Single Parallel Specifies whether the UPS works in single mode or parallel mode Single Single Parallel Requisite modules Matches the system capacity Redundant modules Set this parameter based on load capacity and redundancy requirements 0 0 19 Working mode UPS working mode Normal mode Normal mode ECO Self load mode Converter mode ECO voltage range In ECO mode when the difference between ...

Страница 100: ...e of the place where the rack is used 1000 1000 1000 2000 2000 3000 3000 4000 4000 5000 Air filter maintenance period d Specifies the rack air filter maintenance interval If it is set to 0 there is no reminder 0 0 365 Intra rack power module start delay s These two parameters enable the UPS to control the interval that each rack or module transfers from battery mode to normal mode which reduces th...

Страница 101: ...y and securely Disable Disable Enable Input Settings Figure 4 23 Input settings Item Description Default Value Value Range D G mode Set this parameter to Enable when a D G connects to the input PDC The UPS enters the D G mode when a D G is detected over dry contacts Disable Disable Enable D G power limiting kVA Set these two parameters to control the valid input current and limiting input current ...

Страница 102: ... of the bypass voltage restores to the default value If the voltage level is 380 V or 400 V the default upper limit is 15 If the voltage level is 415 V the default upper limit is 10 400 380 400 415 Output volt adjustment V The output voltage can be slightly adjusted based on the onsite power distribution condition to ensure a minimum difference between the output voltage and the bypass voltage and...

Страница 103: ...s mode If Output freq track rate Hz s is fast the inverter frequency is unstable 0 6 Hz s 0 1 Hz s to 2 0 Hz s Bypass Settings Figure 4 25 Bypass settings Item Description Default Value Value Range Maximum bypass voltage When the difference between the bypass voltage and the rated voltage exceeds the upper threshold for the bypass voltage the system determines that the bypass voltage is not normal...

Страница 104: ...bypass frequency is abnormal so the bypass is unavailable The frequency range must be greater than the ECO frequency range 2 Hz 0 5 Hz to 6 Hz Battery Settings Battery parameter settings impact battery maintenance battery lifespan and UPS discharge time When you set battery parameters note the following Battery string sharing is unavailable when Single Parallel is set as Single Battery string shar...

Страница 105: ...hat is connected in the battery string in series 12 V 2 6 12 Single battery capacity Ah Specifies the capacity of each battery that is connected in the battery string in series Depends on the actual model 5 9999 Batteries in a battery string Specifies the number of batteries in a battery string The default value depends on the model The value range depends on the model Number of battery strings Sp...

Страница 106: ... V cell 1 8 1 9 Dis cur 0 3C EOD V cell 1 80 V cell 1 8 1 9 Dis cur 0 5C EOD V cell 1 75 V cell 1 75 1 85 Dis cur 1 0C EOD V cell 1 60 V cell 1 6 1 75 Sched shallow dis test When certain conditions are met the charger shuts down and batteries supply power to loads The system records the battery discharge data as the reference for battery capacity and lifespan Disable Disable Enable Shallow dis tes...

Страница 107: ...gnals for the battery grounding failure detector D G BCB box and PDCs Backfeed protection board MUE06A provides backfeed protection signals This board can be enabled or disabled Monitoring interface card MUS05A provides four routes of configurable output dry contact signals Dry contact extended card MUE07A provides two routes of input signals and one route of output signals Figure 4 29 Dry contact...

Страница 108: ... User Manual Singapore 35 kVA Power Modules 4 User Interface Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 100 Figure 4 31 Dry contact settings 3 Figure 4 32 Dry contact settings 4 Figure 4 33 Dry contact settings 5 ...

Страница 109: ... 4 User Interface Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 101 Figure 4 34 Dry contact settings 6 Figure 4 35 Dry contact settings 7 Figure 4 36 Dry contact settings 8 Item Description MUE05A connection Specifies the MUE05A connection status Independent ...

Страница 110: ...2 Action MUS05A DO_3 Action MUS05A DO_4 Action Controls the status of DO ports on the MUS05A dry contact card MUE07A DO_1 Action MUE07A DO_2 Action MUE07A DO_3 Action MUE07A DO_4 Action MUE07A DO_5 Action Controls the status of DO ports on the MUE07A extended dry contact card MUE07A DI_1 valid MUE07A DI_2 valid MUE07A DI_3 valid MUE07A DI_4 valid MUE07A DI_5 valid If the DI port valid setting is c...

Страница 111: ...s 2 Item Description Default Value Value Range Language Twelve languages are supported English English Chinese Spanish Dutch French German Italian Polish Portuguese Russian Swedish Turkish Password 000001 password complexity check If the password complexity check is disabled the user password is required to be a string of six to eight digits If the password complexity check is enabled the Enable D...

Страница 112: ... two types of characters 4 1 3 5 Maintenance On the System Info screen tap to display the Maintenance screen Figure 4 39 Maintenance 1 Figure 4 40 Maintenance 2 On the System Info Settings iBOX Settings Basic Param screen if the Number of iBOXs is not 0 the Maintenance is displayed on the iBOX Control screen Choose Monitoring Param Settings System Settings on the WebUI if the Bus capa life is set ...

Страница 113: ...Shallow Dis Test and Capacity Test Figure 4 41 Battery Maint screen Item Description Forced Equalized Charging Forcibly perform equalized charging on batteries Shallow Dis Test Partially discharge batteries A shallow discharge test can be conducted to test the battery loop reliability and short time discharge capacity when the batteries have not discharged for a long time Capacity Test Fully disch...

Страница 114: ...opyright Huawei Technologies Co Ltd 106 Figure 4 42 USB Operations 1 Figure 4 43 USB Operations 2 Starting or Shutting Down the Inverter Item Description Inv ON The Inv ON screen allows you to start the inverter manually Inv OFF The Inv OFF screen allows you to shut down the inverter manually ECM Switchover ...

Страница 115: ...ink Make the red indicator on the iBAT start or stop blinking super fast Internal resistance Measure the battery internal resistance If the condition for measuring internal resistance is met batteries are fully charged you can tap Measure to start measuring the internal resistance of the selected iBAT in an iBOX NOTE The interval between two measurement operations must be greater than 10 minutes B...

Страница 116: ...er are normal No overload alarm is generated SOC 30 Figure 4 44 Wizard startup On the Settings Dry Contact Set screen set MUE05A connection to Enable and set BCB connection OL to Enable Wizard based startup can be used to test the battery switch tripping function 4 1 3 6 About On the About screen you can view the model manufacturer monitoring version and power version Figure 4 45 About ...

Страница 117: ...es 4 User Interface Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 109 4 1 4 System Status On the System Status to view the mains input bypass input load and battery information Figure 4 46 System status 4 1 5 Common Functions Figure 4 47 Common functions 1 ...

Страница 118: ...d 110 Figure 4 48 Common functions 2 4 2 WebUI 4 2 1 Login Context Internet Explorer 11 is used as the example browser The system supports Internet Explorer 11 and Firefox 31 0 Procedure Step 1 Open the browser and choose Tools Internet Options Step 2 On the Advanced tab page ensure that Use TLS 1 0 and Use TLS 1 1 are selected and click OK ...

Страница 119: ... The value range is 1 0 0 0 223 255 255 255 Table 4 12 User description Default User Preset Password User Rights admin system administrator Changeme Performs all operations on the LCD and WebUI including system running information browsing system information exporting parameter setting system control system configuration and system maintenance operator common user Changeme Only browses the system ...

Страница 120: ... logs in to the WebUI if another user logs in with the same user name the current account will be logged out It is advised to change the password after the first login using User Mgmt on the Config page to prevent unauthorized access End 4 2 2 Monitoring Page Figure 4 50 Monitoring page If NA is displayed for load ratio the value is invalid or outside the range When the message Don t let this page...

Страница 121: ...ive Alarms page is displayed by default 3 Information area Displays system monitoring information The parameters that have been introduced in the LCD section are not described in the WebUI section The information displayed in Active Alarms and Real time Data is the same as that on the LCD so the information is not described in the WebUI section 4 2 2 1 Active Alarms On the Active Alarms page you c...

Страница 122: ...PO detection Indicates whether to enable emergency power off EPO EPO is performed only when this parameter is enabled and the EPO switch is triggered When EPO detection is changed from Disable to Enable check that the EPO cable is connected correctly Enable Disable Enable Bus Capa Life If this parameter is set to Enable the UPS detects the bus capacitor lifespan Disable Disable Enable Paral sys hi...

Страница 123: ...p RAM working status is checked regularly If this parameter is set to Disable regular check is disabled Disable Disable Enable Record time after fault Indicates the time for storing fault data after the UPS experiences a fault The default value is 0 ms which means that the data during 20 ms before the fault occurs is recorded If the value is set to 40 ms it means that the data during 20 ms before ...

Страница 124: ...ically This function can be used only when the UPS carries no load Disable Disable Enable Output interruption transfer time ms The interruption for the UPS to transfer from normal mode to bypass mode is 1 2 ms and from bypass mode to normal mode is 0 20 ms Set this parameter based on the output interruption time acceptable to loads 0 0 ms 40 ms 60 ms 80 ms 100 ms 120 ms Max BPM transfer times Cros...

Страница 125: ...lt recovery time When Bus overvoltage recovery is set to Disable the bus overvoltage alarm cannot be automatically cleared and the rectifier and inverter cannot automatically start Enable Disable Enable Bus overvolt recovery time If Bus overvoltage recovery is set to Enable the bus overvoltage alarm is automatically cleared and the rectifier and inverter automatically start when the bus voltage re...

Страница 126: ...ge time When you set battery parameters note the following Retain default settings for Chg cur limiting coef and Cell float voltage Only professional maintenance personnel are allowed to change the settings When you set parameters ensure the following Chg cur limiting coef Transfer to equalized charging cur coef Single batt float chg voltage deviation alarm thres and Single batt dis voltage deviat...

Страница 127: ...qualized charging If the SOC is lower than the specified value batteries start equalized charging 70 0 100 Scheduled equalized charging interval d After batteries transfer from equalized charging to float charging if the batteries do not discharge equalized charging starts only after the float charging time reaches Equalized charging protection interval After equalized charging is complete schedul...

Страница 128: ...e upon EOD 10 1 1440 Undertemp alarm thresh C Battery temperatures can be monitored in a timely manner If a battery overtemperature alarm is detected the charging current limit decreases to 0 03 CA Battery charging stops if a battery overtemperature protection alarm when the temperature reaches the high temperature threshold plus 3 C is generated 5 C 20 C to 5 C Overtemp alarm thresh C 50 C 35 C t...

Страница 129: ...ble Remain cap warning An alarm is generated if this parameter is set to Enable and the remaining capacity is less than the warning threshold Disable Disable Enable Intelligent hibernation If this parameter is set to Enable the intelligent battery hibernation function is enabled Disable Disable Enable Thres of low batt SOC over dry contact If an output dry contact is set to Low battery SOC and the...

Страница 130: ... 3 Query 4 2 3 1 Historical Alarms On the homepage click the Query tab to open the Historical Alarms page for querying historical alarms based on severity generation time and clear time Figure 4 56 Historical alarms 4 2 3 2 Logs On the Logs page you can set Log to Historical logs Cap test logs or Common test logs and query or export logs Historical logs can be exported but not queried ...

Страница 131: ...I user name cannot exceed 10 characters and can contain only uppercase and lowercase letters digits and underscores The password contains 6 to 20 characters and at least two types of uppercase letters lowercase letters digits and underscores If the LUI password complexity check is disabled the user password is required to be a string of six to eight digits If the password complexity check is enabl...

Страница 132: ...server configured with network management system NMS software If SNMP Trap is incorrectly set or not set system information will be lost or not reported in time The certificate is used for Secure Sockets Layer SSL encryption protection for WebUI login You need to apply to a third party institution for the certificate Configuration Management is used to upload and export configuration parameters in...

Страница 133: ...tificate to verify the validity of the ModbusTCP access certificate ModbusTCP Authentication Verify the identity legitimacy of both parties to ensure data security for both parties in ModbusTCP communication After eUPS certificate management is configured a certificate can be imported on the WebUI to replace the preset eUPS certificate 4 2 4 3 RCCMD RCCMD RCCMD function is set to Disable by defaul...

Страница 134: ...pted transmission set on the page of the UPS5000 monitor display module MDU must be the same as the setting on the RCCMD client SSL Encrypted Transmission is set to Enable by default as shown in Figure 4 62 If it is set to Disable the RCCMD certificate controls will not be displayed on the page as shown in Figure 4 63 If SSL Encrypted Transmission is set to Disable a message indicating there is a ...

Страница 135: ...d 127 Figure 4 62 SSL encrypted transmission enabled by default Figure 4 63 SSL encrypted transmission disabled Event Configuration The MDU supports 17 alarm events and a maximum of 50 jobs can be added for each event as shown in Figure 4 64 Figure 4 64 shows the buttons on the Event Configuration page and Table 4 14 describes these buttons ...

Страница 136: ...or expanding all You can view all jobs of all events by clicking this button 2 Button for expanding one event You can view all jobs of the event by clicking this button 3 Button for adding one job You can add one job for the event by clicking this button 4 Button for adding one job for events Select multiple events and you can add one job for the selected events at the same time by clicking this b...

Страница 137: ...n 3 Button for test If you click this button the job will be performed and a message showing test succeeds or fails will be displayed on the page Adding one job for one event Select one event for example Inverter on click the button for adding one job and the page for adding a job for the event is displayed When adding a job the job types to be selected are RCCMD Shutdown RCCMD Message RCCMD Execu...

Страница 138: ...CCMD Message Specify the RCCMD client IP address port and message to be conveyed The RCCMD client will receive the message For example enter This is a test message Figure 4 67 RCCMD message RCCMD Execute Specify the RCCMD client IP address port and command to be executed For example enter SHUTDOWN and the RCCMD client will shut down the computer after receiving the command ...

Страница 139: ... the TRAP message to all connected RCCMD clients based on the sending mechanism If you want to define the TRAP message by yourself you can use the TRAP signal to display the UPS information For example if you enter INVOLT V the RCCMD client will receive the UPS input voltage value for example single phase 220 V three phase A 220 V B 220 V C 220 V Table 4 16 lists the signal names that can be enter...

Страница 140: ... Low battery voltage times N A INPHASES Input phases N A OUTPHASES Output phases N A When you add a job five sending methods are available The latter three methods can take effect only when the event condition is still true after the specified seconds Immediately once After the event happens the job will be sent to the RCCMD client immediately Scheduled in X seconds After the event happens the job...

Страница 141: ...layed The RCCMD certificate RCCMD certificate key and RCCMD CA certificate can be uploaded as shown in Figure 4 70 If the RCCMD certificate or RCCMD CA certificate is not uploaded the default certificate provided by the system is used for communication After the certificate is uploaded successfully click Submit The WebUI of the MDU will restart and the uploaded certificate will be used for communi...

Страница 142: ...he system administrator of the MDU for access rights and add the NMS information to the NMS access list of the MDU The NMS address and access right settings are used for adding information about the NMS accessing the MDU including the NMS address access right and Trap port For details about how to add an NMS over a web browser see Figure 4 72 Figure 4 72 Setting the SNMP Trap Managing the UPS Take...

Страница 143: ...2020 01 10 Copyright Huawei Technologies Co Ltd 135 4 2 5 Maintenance Non professional engineers are not allowed to operate the maintenance page Maintenance functions include calibration variable commissioning upgrade and data download Figure 4 73 Calibration Figure 4 74 Commissioning variables ...

Страница 144: ...CCMD Software 4 2 6 1 Introduction to the Software The RCCMD shutdown software is part of the centralized monitoring system of the Generex network The UPS5000 MDU integrates the functions of the Generex RCCMD server Sends the shutdown command notification message and Trap message to the RCCMD client if the UPS system generates an alarm executes commands on the RCCMD client Receives the message UPS...

Страница 145: ...to select the encrypted transmission All configurations take effect only after restart Figure 4 78 Setting the MDU IPaddress and SSL encrypted transmission mode on the RCCMD client Step 2 On the MDU WebUI choose Config RCCMD and set RCCMD function to Enable Step 3 On the WebUI of the MDU the SSL encryption is set to Enable by default and does not need to be set If the RCCMD client is set to the un...

Страница 146: ...ion function Only when the SSL encryption is enabled on the RCCMD client the logs recorded by the RCCMD client are marked with SSL On the RCCMD client the IP address of the MDU that detects heartbeat needs to be added Then the UPS alive check function is supported the RCCMD can check whether the UPS and RCCMD communicate properly the RCCMD can receive messages sent by the MDU Procedure Step 1 On t...

Страница 147: ... Singapore 35 kVA Power Modules 4 User Interface Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 139 Figure 4 79 Heartbeat detecting mode on the RCCMD client You can also manually detect heartbeat by clicking Run alive check now ...

Страница 148: ...A User Manual Singapore 35 kVA Power Modules 4 User Interface Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 140 Figure 4 80 Detecting heartbeat manually Figure 4 81 Detecting heartbeat manually and successfully End ...

Страница 149: ...re applicable to a single UPS For parallel systems contact Huawei technical support Before powering on the UPS ensure that the UPS has passed all check items in the section Installation Verification Before powering on the UPS ensure that all the UPS switches and upstream switch are OFF Procedure Step 1 Close the upstream bypass and mains input switches After the UPS is powered on initialization be...

Страница 150: ...and date network parameters and system parameters on the Settings Wizard screen Set system parameters with caution because the settings determine normal UPS operation Set Single Parallel after double check Incorrect setting may affect the normal UPS operation Output voltage level refers to the line voltage level Set it based on site requirements Set Output frequency correctly otherwise loads may b...

Страница 151: ...ings Step 2 After you set parameters on the Settings Wizard screen the MDU displays the Bypass mode and No battery alarms which do not need to be handled If there is any other alarm you need to rectify the fault After you set parameters on the Settings Wizard screen choose System Info Settings Advanced Param Check that Requisite modules and Redundant modules match the actual values If dry contact ...

Страница 152: ...reen to start the UPS For online startup activate the startup password on the mobile phone app to start the UPS If the initial startup verification passes startup verification is not required afterwards After factory settings are restored re verification for startup is required Online Startup Step 1 Insert a WiFi module into the USB port on the MDU Step 2 Enable the mobile phone WLAN search for th...

Страница 153: ... that needs to be connected Select UPS5000 in this situation Link Enable the connection between the device and the WiFi network IP UPS IP address which can be obtained from the MDU Port The port number is 443 by default and can be modified If the UPS is managed using the app the port number must be set to 443 Username Password Same as the user name and password of WebUI accounts Step 5 After login...

Страница 154: ...yright Huawei Technologies Co Ltd 146 Figure 5 3 Power on password activation End Offline Startup Step 1 Open the Service Expert app on the mobile phone Step 2 On the home screen of the app tap Startup to access the Set Startup screen Step 3 Set Site and Device Type as required and tap Offline Activation ...

Страница 155: ...tem Info Maintenance Inv ON You can obtain the Bar code and Verification from the screen as shown in the following figure Figure 5 5 Offline startup The values of the Bar code and Verification in the figure are for reference only The actual values prevail Step 5 Enter Bar code and Verification code obtained from the MDU on the Offline Activation screen Tap Generate PWD to generate a startup passwo...

Страница 156: ...on the app Step 6 Enter the generated startup password in Figure 5 5 to start the UPS End 5 1 2 2 Non initial Startup Starting the UPS on the MDU Step 1 Choose Common Functions Inv ON You can also start the inverter by choosing System Info Maintenance Inv ON Step 2 In the displayed login screen select a user name and enter the password Step 3 In the displayed dialog box tap Yes to start the invert...

Страница 157: ...ologies Co Ltd 149 Step 2 Click the Advanced tab check that Use TLS 1 0 and Use TLS 1 1 are selected and then click OK Figure 5 7 Setting the Internet options Step 3 In the address box of the browser enter https UPS IP address Step 4 Enter the correct user name and password and click Login Figure 5 8 Logging in to the WebUI ...

Страница 158: ...esponds to the startup command End 5 1 3 Powering On Loads Context After the inverter starts the UPS works in normal mode The Bypass mode alarm disappears Procedure Step 1 After confirming that the battery strings are properly connected close the battery string input circuit breaker If there are multiple battery strings close the circuit breaker for each battery string and then the general circuit...

Страница 159: ...tting End 5 2 Shutting Down and Powering Off the UPS Context After the inverter is shut down if the bypass is normal the UPS transfers to bypass mode if the bypass is not normal the UPS supplies no power Before shutting down the UPS ensure that all loads have shut down Procedure Step 1 Shut down the inverter On the LCD On the main screen tap Common Functions Tap Inv OFF ...

Страница 160: ...nce screen tap System Info Maintenance On the WebUI Choose Monitoring Control and click Inv OFF In the displayed dialog box click OK to shut down the inverter Figure 5 12 Shutting down the inverter After the inverter shuts down the UPS works in bypass mode if the bypass is normal as shown in Figure 5 13 the UPS supplies no power and the loads power off if the bypass is abnormal as shown in Figure ...

Страница 161: ...o shut down the inverter and transfer the UPS to bypass mode check that the UPS has not generated an alarm and perform Step 1 Step 2 After the inverter shuts down turn off the downstream output switch Step 3 Turn off the battery string circuit breaker If there are multiple battery strings turn off the general circuit breaker between battery strings and the UPS and then turn off the circuit breaker...

Страница 162: ...ART button on the bypass module for at least 2 seconds The system automatically enters the battery cold start status The LCD displays the Huawei logo and an initialization progress bar Step 5 After LCD initialization start the inverter End 5 4 Transferring to Bypass Mode Before shutting down the inverter ensure that the bypass is normal If the bypass is not normal after the inverter is shut down t...

Страница 163: ...e UPS to ECO mode ensure that the bypass module works properly Procedure Step 1 Manually shut down the inverter to transfer the UPS to bypass mode Step 2 Set Working mode to ECO The information stating that the UPS works in ECO mode is displayed on the LCD Step 3 Set the ECO voltage range Figure 5 15 ECO parameters Step 4 Manually start the UPS inverter After the inverter starts the UPS still work...

Страница 164: ...es 5 6 1 Forced Equalized Charging Test Context Before a forced equalized charging test ensure that The mains input is normal Batteries are properly connected Batteries are not in the equalized charging state Procedure Step 1 On the home screen of the LCD choose System Info Maintenance Battery Maint Step 2 Tap Start next to Forced Equalized Charging to start a forced equalized charging test ...

Страница 165: ... discharge test ensure that The UPS works in normal mode with a load ratio fluctuation less than 10 The UPS generates no battery overtemperature overvoltage or overcurrent alarm No generator is connected to the UPS The mains batteries charger and discharger are normal No overload alarm is generated Automatic Shallow Discharge Test Step 1 On the home screen of the LCD choose System Info Settings Ba...

Страница 166: ...fault The discharge voltage reaches the warning threshold calculated in real time The load ratio fluctuation exceeds 10 An alarm is generated End 5 6 3 Capacity Test Context Before a capacity test ensure that The UPS is working in normal mode float charging or hibernation has lasted for 2 hours after the state of charge SOC reaches 100 and the load ratio fluctuation is less than 10 The UPS has gen...

Страница 167: ...ry discharge voltage reaches the EOD voltage plus 0 01 V the test is complete The test data is used as capacity test data Save the capacity test data record with the largest discharge capacity in a month as the capacity test data for the month A maximum of recent 36 capacity test records can be saved End 5 6 4 Test Data Download 5 6 4 1 Download over the LCD Procedure Step 1 Insert a USB flash dri...

Страница 168: ...nologies Co Ltd 160 Figure 5 20 Downloading logs Step 4 Tap Next In the displayed dialog box tap Yes to download data Figure 5 21 Confirming the path End 5 6 4 2 Download over the WebUI Procedure Step 1 Log in to the WebUI Step 2 Choose Query Logs select logs from the Log drop down list box then click Export to export logs ...

Страница 169: ...ock core has a diameter of 5 10 mm Strictly observe the following procedure to transfer the UPS to maintenance bypass mode Otherwise loads may power off In maintenance bypass mode the mains supplies power to the loads directly over the maintenance bypass If the mains is not normal the loads may power off Procedure Step 1 Transfer the UPS to the bypass mode Step 2 Turn on the maintenance bypass swi...

Страница 170: ...ransferring from Maintenance Bypass Mode to Normal Mode Context Before transferring the UPS from maintenance bypass mode to normal mode ensure that the bypass input and output are normal Procedure Step 1 Turn off the maintenance bypass switch by rotating the handle counterclockwise 90 degrees so that the handle points downwards The Maint Breaker closed alarm disappears from the alarm list Check wh...

Страница 171: ...power supplied alarms are displayed on the LCD 5 10 Clearing the EPO State Procedure Step 1 Clear the EPO state Ensure that the EPO button connected to the dry contact is not in the EPO state Step 2 Clear the EPO alarm On the LCD On the LCD choose System Info Alarms and tap Clear Faults In the displayed dialog box tap Yes The EPO alarm is cleared successfully On the WebUI Choose Monitoring Control...

Страница 172: ... have logged in to the WebUI Context The following data can be exported Historical alarms Logs E Label Fault Data This topic describes how to export historical alarms Procedure Step 1 Choose Query Historical Alarms and set Severity Generated and Cleared Figure 5 25 Querying historical alarms You do not need to query logs Choose Query Logs click Export and save the file Step 2 Click Query and you c...

Страница 173: ...UPS5000 S 35 kVA 210 kVA User Manual Singapore 35 kVA Power Modules 5 Operations Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 165 Step 3 Click Export and save the displayed webpage End ...

Страница 174: ... maintained contact Huawei technical support Only maintenance engineers can maintain power modules and bypass modules Maintain UPSs regularly based on the following requirements Otherwise the UPSs may fail to operate properly and the service life may be shortened 6 1 1 Monthly Maintenance Table 6 1 Monthly maintenance Check Item Expected Result Troubleshooting Operating environment Ambient tempera...

Страница 175: ...binet surface using a white paper and the paper does not turn black Remove the dust especially from the air filter on the front door or replace the air filter Parameter configuration The configuration of the output voltage grade frequency number of batteries and battery capacity meets requirements Reset the parameters Status record Record the three phase load rate and output power factor If an exc...

Страница 176: ... components and recommended replacement intervals Key Component Design Service Life Recommended Replacement Interval Power module 15 years 10 years Bypass module 15 years 10 years Fan 15 years 10 years LCD screen 10 years 8 years 6 2 Battery Maintenance Before installing batteries read through the battery user manuals and pay attention to safety precautions and connection methods provided by batte...

Страница 177: ...s 2 The battery terminals are intact 3 Batteries are free from damage and cracks 4 Batteries are free from acid leakage 5 Batteries are not deformed or bulged If the battery appearance is abnormal contact Huawei technical support Battery operating temperature 1 The ambient battery temperature is 25 5 C 2 The battery operating temperature is lower than battery temperature 20 C 3 Battery charge and ...

Страница 178: ...ws The location of the signs marked on battery terminals indicating tight connections does not change Take photos from multiple angles and contact Huawei technical support Cables between batteries No cable deteriorates and the insulation layer does not crack Replace the faulty cable Battery voltage Equalized charging voltage 2 35 V cell 0 02 V cell Float charging voltage 2 25 V cell 0 02 V cell 1 ...

Страница 179: ...n is identified 2 If the fault persists contact Huawei technical support Battery connection reliability 1 Each battery terminal is connected reliably When battery strings are powered off check the reliability of each terminal in the order from positive terminals to negative terminals 2 The tightening torque of each battery screw meets the requirements of the battery manufacturer A torque wrench is...

Страница 180: ...x trips if the BCB box is configured To restore battery discharge close the battery switch in the BCB box if any first To restore battery discharge after batteries reach EOD use one of the following methods 1 Switch to another battery string Ensure that each battery has a voltage greater than the EOD voltage and 11 3 V cell 2 Restore the mains power supply to start the inverter Close the battery s...

Страница 181: ...place the power module The charger experiences overcurrent Replace the power module The charger experiences undervoltage Check whether the configured number of batteries is correct If the value is correct but the alarm persists replace the power module The UPS works in bypass mode and does not transfer to inverter mode When the mains is normal the UPS works in bypass mode and does not transfer to ...

Страница 182: ...S485 ports and FE ports Supports Simple Network Management Protocol SNMP Dimensions H x W x D 2000 mm x 600 mm x 850 mm Weight 515 kg Table 8 2 Environmental specifications Item Specifications Operating temperature 0 C to 50 C Storage temperature 40 C to 70 C Relative humidity 0 95 RH non condensing Altitude 0 1000 m When the altitude is greater than 1000 m and less than 4000 m the rated power sho...

Страница 183: ...bility CS EN IEC62040 2 EN IEC61000 4 6 EN50121 5 Radiated susceptibility RS EN IEC62040 2 EN IEC61000 4 3 EN50121 5 Electrical fast transient EFT EN IEC62040 2 IEC61000 4 4 EN50121 5 Surge EN IEC62040 2 IEC61000 4 5 EN50121 5 Power magnetic susceptibility PMS IEC61000 4 8 EN50121 5 Voltage dip and short interruption IEC61000 4 11 Table 8 4 Mains input electrical specifications Item Specifications...

Страница 184: ...pecifications Item Specifications Input system Three phase four wire and PE Rated input voltage 380 V AC 400 V AC or 415 V AC line voltage Rated frequency 50 Hz or 60 Hz Input frequency 50 60 Hz 6 Hz adjustable with the tolerance of 0 5 6 Hz 2 Hz by default Input system The mains input and bypass input can share a power source or use different power sources Table 8 6 Battery electrical specificati...

Страница 185: ... Item Specifications Output system Three phase four wire and PE Voltage 380 V AC 400 V AC 415 V AC line voltage Frequency In normal mode the frequency is synchronous with the bypass input frequency In battery mode the frequency is 50 Hz 60 Hz with a tolerance of 0 05 THDv THDv 1 full linear load THDv 4 full non linear load Output PF 1 Transfer time 0 ms uninterruptible transfer 20 ms interruptible...

Страница 186: ... Power Modules 8 Technical Specifications Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 178 Table 8 8 System electrical specifications Item Specifications Parallel system reliability Redundant parallel signals ECO in a parallel system Supported ...

Страница 187: ... circuiting the Input N and PE Issue 02 2020 01 10 Copyright Huawei Technologies Co Ltd 179 A Short circuiting the Input N and PE The recommended cable cross sectional area is 150 mm2 The following cable connection is for reference only Figure A 1 Connecting the input N and PE ...

Страница 188: ...evel 3 Menu Level 4 Menu System Info Runn Info AC Output N A UPS Load N A Mains Input N A Bypass Input N A Battery Status N A Module Data N A Total Runtime N A Environment Data N A Alarms Active Alarms N A Historical Alarms N A Buzzer Off N A Clear Faults N A Settings Comm Settings IP Settings RS485 Settings ModbusTCP Settings Amb T H Sensor Batt Temp Sensor WiFi Settings System Settings N A Input...

Страница 189: ...N A Dry Contact Set N A Settings Wizard N A User Settings N A Maintenance Battery Maint N A USB Operations Fault data Upgrade Software BSP Upgrade Import Config Export Config Multi brand Remove USB Inv ON N A Inv OFF N A ECM Switchover N A Screen Calib N A About N A N A Common Functions AC Output N A N A UPS Load N A N A Mains Input N A N A Inv ON N A N A Inv OFF N A N A Buzzer Off N A N A Histori...

Страница 190: ...itoring Active Alarms N A Real time Data UPS Module Param Settings System Settings Input Settings Output Settings Bypass Settings Battery Settings Dry Contacts Comm Config IP Settings RS485 Settings ModbusTCP Settings Amb T H Sensor Batt Temp Sensor WiFi Settings iBOX Settings Basic Param Advanced Param Batt String Config Control System Commands and Tests Query Alarm History N A Logs N A Config Us...

Страница 191: ...gement Multi brand Management Configure Alarm Notification Server Configure Alarm Notification Email Address ModbusTCP Certificate Management ModbusTCP CA Certificate Management ModbusTCP Authentication eUPS Certificate Management RCCMD RCCMD SSL Encrypted Transmission Event Configuration RCCMD Certificate Management Maint Calib Bypass Module ECM Commissioning Var Bypass Module ECM Upgrade Softwar...

Страница 192: ...power module is not normal Replace the faulty module 3 Check whether the output or battery is incorrectly grounded 0001 2 Cable connections are incorrect The mains is not normal The mains input fuse for the power module is blown 1 Check whether cables to mains are disconnected loose or incorrectly connected 2 If cable connections are correct measure the mains voltage with a multimeter If the mains...

Страница 193: ...nections with a multimeter 2 Check the bypass input frequency Check the rated frequency and frequency range configured on the LCD 0011 1 Bypass phase reversed Minor The phase sequence of the three phase bypass input is reversed Check whether the cable phase sequence is correct using a multimeter If no multimeter is available exchange the positions of any two cables 0012 1 Bypass neutral absent Min...

Страница 194: ... installed properly The charger is faulty 1 If the low battery voltage alarm is generated in battery mode check whether the mains voltage recovers If yes charge batteries immediately 2 Check whether the battery neutral wire is correctly connected 3 If this alarm is generated in normal mode check whether the battery switch is ON If yes the charger may be faulty Replace the related power module 0530...

Страница 195: ...an extended amount of time The charger is faulty 1 Check whether the battery voltage is normal 2 Check whether the output is overloaded 3 Check whether any battery is damaged If yes replace the battery 4 Check whether any battery charger generates an alarm If yes replace the faulty module 0040 7 Rectifier abnormal Critical The fan for the power module is not functioning properly The air channel fo...

Страница 196: ...hether the alarm is cleared 2 If the alarm is generated again replace the power module 0061 7 Inverter alarm Minor The bypass waveform is not normal If not all modules generate the alarm start the UPS transfer it to normal mode and replace the faulty module If all modules generate the alarm open the bypass input circuit breaker After the inverter relay is closed close the bypass input circuit brea...

Страница 197: ...el is blocked The ambient temperature exceeds the upper threshold The load is excessive 1 Check the bypass fan and air channel If the fan is faulty replace it 2 Check that the ambient temperature has not exceeded 40 C 3 Check that there is no overload 0583 1 Inter rack par cable abnormal Critical The inter rack parallel system CAN bus is disconnected or short circuited Only one rack works in a par...

Страница 198: ...o bypass mode 0088 1 Rack address conflict Critical The configured rack address conflicts with another one Check the rack address setting 0089 1 Rack output overload Minor The load is excessive The rack capacity setting is not appropriate Check the load and remove some loads or expand the UPS power capacity if the UPS is overloaded Check that the configured rack capacity meets requirements 0090 1 ...

Страница 199: ...breaker is OFF The running status is displayed No further measures are required 0343 BPM input breaker open Critical The bypass input circuit breaker is OFF The running status is displayed No further measures are required 0340 Maint breaker closed Minor The maintenance circuit breaker is ON The running status is displayed No further measures are required 0335 Generator connected Warning The genera...

Страница 200: ...N 2 Check that bypass input and output power cables on each rack meet the length requirements 3 Rectify any bypass SCR open circuit 0150 1 Inverter asynchronous Minor The bypass frequency changes fast The output frequency track rate is incorrectly set 1 Check that the bypass output frequency does not change fast 2 Check that the Output freq track rate is properly set 0101 1 BSC signal abnormal Min...

Страница 201: ...it ATS AC transfer switch AWG American wire gauge B BSC bus synchronization controller BCB BOX battery circuit breaker box BBB BOX battery bus bar box C CAN control area network CE Conformite Europeenne D DSP digital signal processing E ECO economy control operation EPO emergency power off ECM energy control module EOD end of discharge F FE fast Ethernet I IEC International Electrotechnical Commis...

Страница 202: ...negative temperature coefficient P PE protective earthing PDU power distribution unit R RS485 Recommend Standard 485 S SNMP Simple Network Management Protocol SOC state of charge SOH state of health STS static transfer switch T THDi total distortion of the input current waveform THDv total harmonic distortion of output voltage U UPS uninterruptible power system USB Universal Serial Bus V VRLA valv...

Отзывы: