SUN2000L-(2KTL-5KTL)
User Manual
5 Electrical Connections
Issue 02 (2017-12-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
49
Figure 5-16
Removing a DC connector
5.5 Installing the Battery Cable
Prerequisites
Battery short circuits may cause personal injury. The high transient current generated by a
short circuit will release a surge of power and may even cause fire.
Do not connect or disconnect battery cables when the SUN2000L is running. Failing to do
so may cause electric shocks.
Before connecting battery cables, ensure that the DC switch on the SUN2000L and all the
switches connecting to the SUN2000L are OFF, and the SUN2000L has no residual
electricity. Otherwise, the high voltage of the SUN2000L and battery may result in electric
shocks.
If no battery connects to the SUN2000L, do not remove the watertight cap from the battery
terminal. Otherwise, the SUN2000L will not comply with its Ingress Protection Rating. If
a battery connects to the SUN2000L, set aside the watertight cap. Reinstall the watertight
cap immediately after removing the connector. The high voltage of the battery terminal
may result in electric shocks.
A battery switch can be configured between the SUN2000L and the battery to ensure that the
SUN2000L can be safely disconnected from the battery.
Do not connect any load between the SUN2000L and the battery.
Ensure that the following conditions are met. Otherwise, the SUN2000L will be damaged, or
even become a fire hazard.