HUAWEI TECHNOLOGIES CO., LTD.
SUN2000L-(2KTL-5KTL)
Quick Guide
Issue: 04Part Number: 31508725Date: 2019-04-27
Страница 1: ...HUAWEI TECHNOLOGIES CO LTD SUN2000L 2KTL 5KTL Quick Guide Issue 04 Part Number 31508725 Date 2019 04 27 ...
Страница 2: ...PPE all the time 4 Before installing the device check that the package contents are intact and complete against the packing list If any damage is found or any component is missing contact your dealer 5 Huawei shall not be liable for any device damage caused by the violation of instructions in this document 6 The cable colors involved in this document are for reference only Select cables in accorda...
Страница 3: ...lve 7 DC switch DC SWITCH 8 DC input terminals PV1 PV1 9 DC input terminals PV2 PV2 10 Battery terminals BAT BAT 11 COM port COM 12 AC output port AC 13 Antenna port ANT 14 Alarm port ALARM 15 Ground point Installation Requirements 3 1 2 Overview 3 Installing the Device Tilt and Space 2 ...
Страница 4: ...s need to be installed see SUN2000L 2KTL 5KTL User Manual for the installation dimensions Installing the Mounting Bracket 3 2 Avoid drilling holes in the utility pipes and or cables attached to the back of the wall Wall mounted Installation ...
Страница 5: ...dvised to apply anti rust paint on the hole positions for protection If the bottom of the mounting plate does not snap into place push the SUN2000L from the front until the bottom of the mounting plate snaps into the mounting bracket The anti theft lock needs to be prepared by the customer 1 Install the SUN2000L on the mounting bracket 2 Tighten screw assemblies 3 Optional Install an anti theft lo...
Страница 6: ... 4 Signal cable optional Four core outdoor shielded twisted pair 0 25 1 mm2 4 11 mm Connect cables in accordance with the installation laws and regulations of the country or region where the SUN2000L is located Before connecting cables ensure that the DC switch on the SUN2000L and all the switches connecting to the SUN2000L are OFF Otherwise the voltage of the SUN2000L may result in electric shock...
Страница 7: ...ended Apply silica gel or paint around a ground terminal after connecting the ground cable NOTE 1 Connect the AC output power cable to the AC connector Installing the AC Output Power Cable 4 3 Ensure that the protection layer of the AC output power cable is in the connector and that the exposed core wire is totally inserted into the cable hole and connected securely Failing to do so may cause SUN2...
Страница 8: ...7 Click 2 Connect the AC connector to the AC output port and then Check the route of the AC output power cable AC output port AC Two Core Cable L and N ...
Страница 9: ... Use the positive and negative metal terminals and black DC connectors supplied with the inverter Using incompatible positive and negative metal terminals and DC connectors may result in serious consequences The caused device damage is not covered under any warranty 7 If polarity of the DC input power cable is reversed and the DC switch is ON do not turn off the DC switch immediately or unplug pos...
Страница 10: ...ng metal stamping forming contacts Ensure that the cable will not be extracted after crimped Positive metal terminal Negative metal terminal Positive connector Negative connector Ensure that the locking nut is secured Ensure that the cables are correctly connected Pull the DC input power cable back to ensure that it is connected securely Click ...
Страница 11: ... damaged Battery terminals BAT BAT Optional Installing the Signal Cable 4 6 When laying out signal cables separate them from power cables to avoid strong signal interference The protection layer of the signal cable is in the connector Surplus core wires are cut off from the protection layer The exposed core wire is totally inserted into the cable hole and connected securely Do not confuse the conn...
Страница 12: ...485A1 RS485A RS485 differential signal 3 485B2 RS485B RS485 differential signal Connect to the RS485 signal port and enable signal port on a battery 4 485A2 RS485A RS485 differential signal 5 EN Enable signal 6 EN Enable signal 7 N A N A N A 8 PE Grounding the shield layer Connects to the shield layer of the cable Click COM Port Pin Definitions ...
Страница 13: ...nal Connect to the RS485 signal port on SmartPSB2000L smart PV safety box Connect to the power port on SmartPSB2000L smart PV safety box 4 485A3 RS485B RS485 differential signal 5 12V Negative of the 12 V power supply 6 12V Positive of the 12 V power supply 7 N A N A N A 8 PE Grounding the shield layer Connects to the shield layer of the cable Click ALARM Port Pin Definition ...
Страница 14: ...is clean and tidy 5 Verifying the Installation 6 Powering On the System Before turning on the AC switch between the SUN2000L and the power grid check whether the AC voltage is within the specified range If the inverters are connected to batteries turn on the DC switch within 1 minute after turning on the AC switch Otherwise the inverters connected to the power grid will shut down and start again 1...
Страница 15: ...exporting power to the power grid Off Off Both the DC and AC are off or the SUN2000L is in low power consumption mode Steady red Steady red The SUN2000L is faulty Communicati on indication LED3 N A Blinking green at short intervals The SUN2000L is in communication Blinking green at long intervals The SUN2000L has connected to the mobile phone Off No communication 7 Commissioning The screenshots sh...
Страница 16: ... If you have an installer account skip this step NOTE Creating the first installer account will generate a domain named after the company To create multiple installer accounts for the same company log in to the FusionSolar and tap New User 15 ...
Страница 17: ...FusionSolar App Quick Guide You can scan the QR code to obtain it 3 Creating a PV Plant and an Account for User Scenario 2 Inverter commissioning 7 2 1 Access Inverter commissioning Method 1 before login Method 2 after login 16 ...
Страница 18: ...n and change it immediately after login To ensure account security change the password periodically and keep the new password in mind Not changing the initial password may cause password disclosure A password left unchanged for a long period of time may be stolen or cracked If a password is lost devices cannot be accessed In these cases the user is liable for any loss caused to the PV plant To set...
Страница 19: ..._ESC ms huawei com 0120258367 India India indiaenterprise_TAC huawei com 1800 103 8009 Korea Korea Japan_ESC ms huawei com North America United States na_inverter_support huawei com 1 877 948 2934 Canada na_inverter_support huawei com 1 855 482 9343 Latin America Mexico la_inverter_support huawei com 018007703456 0052 442 4288288 Argentina 0 8009993456 Brazil 0 8005953456 Chile 800201866 Only for ...
Страница 20: ...Huawei Technologies Co Ltd Huawei Industrial Base Bantian Longgang Shenzhen 518129 People s Republic of China solar huawei com ...