Figure 7-24
Querying EMI-related information
You can click the
,
, or
tab on
the tertiary navigation menu to query EMI-related information.
EMI performance data can be stored for three months and exported. When changing the name of the
exported file, retain the extension
.tar.gz
. Otherwise, the file may be unavailable.
When the SmartLogger connects to multiple EMIs and a master EMI is set, the
Performance Data
page displays the data about the master EMI. When the SmartLogger connects to multiple EMIs and
no master EMI is set, the
Performance Data
page displays the data about any EMI.
7.8.5.2 Setting Running Parameters
Connection over the COM Port
After the SmartLogger connects to the EMI, you need to add the device manually. For details,
see
Device Type
should be set to
EMI
, and
Connection mode
to
Modbus-RTU
.
Devices from different vendors may support different protocol specifications. To normally
obtain information from the connected EMI, correctly configure the protocol specifications on
the WebUI of the SmartLogger based on the protocol specifications delivered by the vendor.
Because of permission restriction, log in as
Advanced User
. Choose
Monitoring
>
EMI
>
EMI(COMX)
>
Running Param.
, and set EMI parameters.
X
in
COMX
indicates any digit from 1 to 6. The actual COM port to which the EMI connects prevails.
If the EMI model is displayed in the drop-down list box, select it.