snmp-agent group v3 group1 privacy read-view hardy write-view hardy
snmp-agent mib-view hardy include internet
snmp-agent sys-info contact HW-075528780808
snmp-agent sys-info location Shenzhen_China
snmp-agent local-engineid 0123456789
snmp-agent sys-info version v3
snmp-agent trap enable standard
snmp-agent target-host trap-hostname huawei address 10.10.1.10 trap-paramsname ABC
snmp-agent target-host trap-paramsname ABC v3 securityname user1 privacy
snmp-agent trap source meth 0
save
The following part provides the script for configuring the inband NMS (on the device). The
management VLAN ID of the upstream port is 30.
snmp-agent usm-user v3 user1 group1 authentication-mode md5 authkey123 privacy-mode
des56 prikey123
snmp-agent group v3 group1 privacy read-view hardy write-view hardy
snmp-agent mib-view hardy include internet
snmp-agent sys-info contact HW-075528780808
snmp-agent sys-info location Shenzhen_China
snmp-agent local-engineid 0123456789
snmp-agent sys-info version v3
snmp-agent trap enable standard
snmp-agent target-host trap-hostname huawei address 10.10.1.10 trap-paramsname ABC
snmp-agent target-host trap-paramsname ABC v3 securityname user1 privacy
snmp-agent trap source vlanif 30
save
3.3 Configuring the Attributes of the Upstream Port
The MA5616 can be interconnected with the OLT through upstream GPON/GE port. This topic
describes how to configure the attributes of upstream GPON/GE port so that the device
communicates successfully with the upstream device.
3.3.1 Configuring an Uplink Ethernet Port
This topic describes how to configure a specified Ethernet port so that the system communicates
with the upstream device in the normal state.
Context
The MA5616 should be interconnected with the upstream device through the Ethernet port.
Therefore, pay attention to the consistency of port attributes.
The MA5616 supports Ethernet cascading network. On the network, multiple devices can be
cascaded using GE ports to extend the network coverage and meet the requirements for large
access capacity. When two MA5616s are cascaded, set GE port 0 on the upper-layer device as
the cascaded port and set GE port 0 on the lower-layer device as the uplink port. For details
about the configuration principles, see
SmartAX MA5616 Multi-service Access Module
Configuration Guide
3 Basic Configuration
Issue 04 (2011-10-30)