Figure 1-9
Configure the IP address and the subnet mask
NOTE
The IP address of the maintenance terminal and the IP address of the maintenance Ethernet
port of the device must be in the same network segment.
6.
Click
OK
to return to the
Local Area Connection Properties
dialog box.
7.
Click
OK
.
----End
Result
The IP address of the maintenance terminal and the IP address of the maintenance Ethernet port
of the device are in the same network segment.
NOTE
By default, the IP address of the maintenance network port (ETH port on the control board) is 10.11.104.2,
and the subnet mask is 255.255.255.0.
1.3.5 Logging In to the System
You must log in to the MA5600T/MA5603T/MA5608T before commissioning the MA5600T/
MA5603T/MA5608T through the maintenance terminal. The following describes three login
modes, namely, local serial port mode, telnet mode, and SSH mode. SSH with high priority is
recommended.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
1 Commissioning
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
20