14.4.9.7 Verifying Services
The Ethernet base station access service can be verified by checking the connectivity and alarms
of the service.
Prerequisites
The base station access service has been deployed.
Procedure
Step 1
Check connectivity.
1.
Check the connectivity between base stations and the IP clock server.
On base stations, configure management IP addresses and static routes to the IP clock
server, and then perform ping operations. In normal cases, the ICMP ECHO-REPLY
message can be received from the IP clock server.
2.
Check the connectivity between base stations and the OAM server.
On base stations, configure IP addresses of management channels and static routes to the
OAM server, and then perform ping operations. In normal cases, the ICMP ECHO-REPLY
message can be received from the OAM server.
3.
Check the connectivity between base stations and the RNC.
On base stations, configure service port IP addresses and static routes to the RNC, and then
perform ping operations. In normal cases, the ICMP ECHO-REPLY message can be
received from the RNC.
Step 2
Check alarms.
Check logs on base stations. Verify that no alarms are generated within 24 hours.
----End