SmartACU2000D Smart Array Controller
User Manual (with No PID Module)
4 System Installation
Issue 01 (2020-02-14)
Copyright © Huawei Technologies Co., Ltd.
42
4.5 Installing the Components
Install the components based on
2.6 Configuration in Different Scenarios
4.5.1 Opening the Main Cabinet Door
Before opening the main cabinet door, turn off all upstream switches for the SACU to
power off the SACU. After that, wait at least 3 minutes and operate the SACU. If you have
to operate an energized SACU, wear insulation gloves and take preventive measures.
If you need to open the main cabinet door on rainy or snowy days, take protective
measures to prevent rain or snow from entering the cabinet. If it is impossible to take
protective measures, do not open the main cabinet door on rainy or snowy days.
Do not leave unused screws in the cabinet.
Loosen the screws on the main cabinet door, open the cabinet door, and adjust the support bar.
Figure 4-10
Opening a cabinet door
To highlight the involved area, the figure does not show certain components. This is applicable to all
other similar figures.
4.5.2 (Optional) Installing the SmartModule
Step 1
Remove the mounting ears and guide rail–mounting kit from the SmartModule.
Step 2
Remove the panel at the position where the SmartModule is to be installed from the cabinet
and take out the mounting kit.
Step 3
Secure the mounting bracket to the SmartModule.
Step 4
Install the SmartModule.