An interface is configured as the uplink interface or downlink interface of the Monitor Link
group.
Or run:
smart-link group
group-id
uplink
An interface cannot be added to a Monitor Link group in the following situations:
l
The interface is added to an Eth-Trunk.
l
The interface is added to a Smart Link group.
l
The interface is added to another Monitor Link group.
A Smart Link group is configured as the uplink interface of the Monitor Link group.
NOTE
The status of the uplink interface determines the status of the Monitor Link group. Therefore, after the
downlink interface is added to the Monitor Link group, the result of the
shutdown
or
undo shutdown
command can be retained before the status of the uplink interface changes. When the status of the uplink
interface changes, the status of the downlink interfaces changes as follows:
l
When an uplink interface in Up state is added to the Monitor Link group or when an uplink interface
in Down state becomes Up, all the downlink interfaces in the Monitor Link group become Up.
l
When an uplink interface is deleted from the Monitor Link group or when an uplink interface in Up
state becomes Down, all the downlink interfaces in the Monitor Link group become Down.
To add a Smart Link group to a Monitor Link group, you need to delete the existing uplink interface of the
Monitor Link group. The Smart Link group and common interfaces are incompatible when serving as the
uplink interface for a Monitor Link group.
----End
2.4.4 Setting the Revertive Switching Interval of a Monitor Link
group
Context
Do as follows on SwitchA and SwitchB.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
monitor-link group
group-id
The Monitor Link group view is displayed.
Step 3
Run:
timer recover-time
recover-time
The interval of revertive switching is set.
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
2 Smart Link and Monitor Link Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
31