Figure 8-28
Installing a CPRI optical cable
NOTICE
To avoid any damage to optical cables, the cables connected to the RRU must be installed
according to the installation process. For details about the installation process, see
.
Step 3
Connect the end labeled 2A and 2B of the optical cable to the optical module on the BBU side.
Step 4
Route the cables according to the instructions in
, and then use cable
ties to bind the cables.
Step 5
Label the installed cables according to the instructions in Attaching an L-Shaped Label.
----End
8.11 Installing an RRU Power Cable
This section describes the procedure for installing an RRU power cable.
Prerequisites
l
A tool-less female connector (pressfit type) is added to the RRU power cable on the RRU
side. For details, see
11.1 Adding a Tool-Less Female Connector (Pressfit Type) to the
RRU Power Cable on the RRU Side
.
8 Installing RRU Cables
Issue ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.