Figure 3-42
Installing the camera's power adapter
3.7 Troubleshooting
3.7.1 Unbalanced Rack
Symptom
The rack is unbalanced after being taken out of the packing case.
Cause
The wheels of the rack are not level.
Installation Techniques
Use the M10 open-ended wrench to adjust the wheels. The wheel height rises when you turn the
wrench counterclockwise and lowers when you turn the wrench clockwise, as shown in
.
HUAWEI RP100&RP200 Room Presence
Commissioning Guide
3 Installation
Issue 01 (2015-02-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
44