Huawei R95021G1 Скачать руководство пользователя страница 1

1

Indicator

Status

Description

Running 
indicator 
(green)

Steady on

Normal status

Off

The charger has no AC input.

Blinking fast (on for 
0.125s and then off 
for 0.125s)

The charger is being queried.

Blinking slowly (on
for 1s and then off 
for 1s)

The charger is in sleep state.

Alarm 
indicator 
(yellow)

Off

Normal status

Steady on

Ambient undertemperature, or 
overtemperature alarm

AC input overvoltage, undervoltage, 
open phase, or serious voltage 
imbalance

Serious imbalance of internal bus 
voltage, overvoltage, or undervoltage

Current imbalance

Charger missing

Soft address conflict

Protection caused by other 
abnormalities

Blinking fast (on for 
0.125s and then off 
for 0.125s)

The charger is being tested.

Blinking slowly (on 
for 1s and then off 
for 1s)

The charger has failed to communicate. 

Fault 
indicator 
(red)

Off

Normal status

Steady on

Lockout due to output overvoltage

Lockout due to an output short circuit

Communication failure between the 
primary side and the secondary side

Fan fault

Internal overtemperature protection

Abnormal output discharge circuit

Unrecoverable no-output breakdown

Faults caused by other abnormalities

Run, alarm, 
and fault 
indicators

The green, yellow, 
and red indicators 
blink cyclically.

An application program is being loaded.

Issue: 01
Date: 2018-12-11

R95021G1 Charger 
Quick Guide

1

Overview

(1) Barcode (cover 
interior)

(2) Running indicator (3) Alarm indicator

(4) Fault indicator

(5) Warranty label

(6) Barcode

(7) Mounting ear 
(optional) 

(8) DC output port

(9) AC input port

Model

R95021G1

Weight

• 12 kg (without packaging)
• 14 kg (with packaging)

Dimensions (H x W x D)

83 mm x 206 mm x 470 mm

Front

Rear

Copyright © Huawei Technologies Co., Ltd. 2018. All rights reserved.

1. The information in this document is subject to change due to version upgrades or other reasons. Every effort has been made in the 

preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do 
not constitute a warranty of any kind, express or implied.

2. Before installing the device, carefully read the user manual to get familiar with product information and safety precautions. You can log in to 

http://support.huawei.com/enterprise/ and search for the device model on the Product Support tab page to view or obtain the user manual.

3. Only qualified and trained electrical technicians are allowed to operate the device. Operation personnel must wear proper personal protective 

equipment (PPE) all the time.

4. The charger module does not have the battery reverse-connection prevention function. The charging machine (pile) needs to detect battery 

reverse-connection prevention. The module failure caused by battery reverse-connection is not covered under the warranty.

5. When operating Huawei equipment, follow the precautions and special safety instructions provided by Huawei. Huawei will not be liable for 

any consequences that are caused by the violation of safety regulations and design, production, and usage standards.

6. Do not remove the warranty label or barcode from the charger. Otherwise, product warranty will be forfeited.

Содержание R95021G1

Страница 1: ...ing ear optional 8 DC output port 9 AC input port Model R95021G1 Weight 12 kg without packaging 14 kg with packaging Dimensions H x W x D 83 mm x 206 mm x 470 mm Front Rear Copyright Huawei Technologies Co Ltd 2018 All rights reserved 1 The information in this document is subject to change due to version upgrades or other reasons Every effort has been made in the preparation of this document to en...

Страница 2: ...idewards or vertically with the panel at the bottom If side or vertical installation is adopted ensure that mechanical parts are designed to avoid interference The installation mode can be selected according to the actual situation Horizontal installation is recommended and vertical installation is not recommended Horizontal Installation Recommended 1 Optional Determine whether to install the moun...

Страница 3: ...ture resisting cables Cross sectional area 6 mm2 BVR ZR 105 flame retardant 105 C flexible wire CAN communications cable Shielded twisted pair minimum cross sectional area 0 08 mm2 28 AWG maximum cross sectional area 1 5 mm2 16 AWG N A Preparing Cables 3 1 DC output DC output address line charger in position detection and control ground signals are hazardous voltages please don t touch Input Termi...

Страница 4: ... metal terminals must be reliably crimped Minimum pulling out force 300 N for the cross sectional area 5 26 mm2 or 350 N for the cross sectional area 6 mm2 NOTE The DC output terminal can be installed in the following two scenarios Install it based on the site requirement Used with an address board DC output terminal and address board supplied by the user Not used with an address board DC output t...

Страница 5: ...sectional area 5 26 mm2 or 350 N for the cross sectional area 6 mm2 NOTE Huawei Technologies Co Ltd Huawei Industrial Base Bantian Longgang Shenzhen 518129 People s Republic of China www huawei com Email solarservice huawei com 4 Set the address DIP switch Hardware address 6 x ON switch No of S1 1 ON switch No of S2 Switches 1 6 of S1 correspond to row addresses 1 6 Switches 1 6 of S2 correspond t...

Отзывы: