Command Manual – ARP
Quidway S3900 Series Ethernet Switches-Release 1510
Chapter 2 Resilient ARP Configuration
Commands
Huawei Technologies Proprietary
2-1
Chapter 2 Resilient ARP Configuration Commands
2.1 Resilient ARP Configuration Commands
2.1.1 display resilient-arp
Syntax
display resilient-arp
[
unit unit-id
]
View
Any view
Parameter
unit-id
: Unit ID ranging from 1 to 8.
Description
Use the
display resilient-arp
command to display the Resilient ARP state information
of each unit and the VLAN interface that can transmit Resilient ARP packets.
If the
unit-id
is not specified, this command is to display Resilient ARP state information
of all units. If the
unit-id
is specified, this command is to display the Resilient ARP state
information of the specified unit.
Example
# Display the information about Resilient ARP state of unit 1.
<Quidway> display resilient-arp unit 1
The state of unit 1 is: L3Master
The sending interface(s):
Vlan-interface1
Vlan-interface2
The above information displayed means that the current Resilient ARP state of unit 1 is
L3Master. Under this status, switch sends Resilient ARP packets periodically to notify
other fabrics that the local fabric is in the Layer 3 state. And VLAN interfaces through
which the Resilient ARP packets are sent are VLAN 1 interface and VLAN 2 interface.
2.1.2 resilient-arp enable
Syntax
resilient-arp enable