Field
Value Range
Description
Check Field Length
The value ranges of the
parameters are different from
each other for different
boards and products. You can
click the hyperlink in the
description to display the
specific information.
The
Check Field Length
parameter specifies the length
of the CRC field of the
mapping protocol.
You can set this parameter
only when the mapping
protocol is GFP, HDLC, or
LAPS.
You can click
to display the
detailed information.
FCS Calculated Bit
Sequence
The value ranges of the
parameters are different from
each other for different
boards and products. You can
click the hyperlink in the
description to display the
specific information.
The
FCS Calculated Bit
Sequence
parameter
specifies the sequence of
storing the bits in the CRC
field of the mapping protocol.
You can set this parameter
only when the mapping
protocol is GFP, HDLC, or
LAPS.
You can click
to
display the detailed
information.
4.11.7 Bound Path
This topic describes the parameters, such as available resources, available timeslots, and service
direction, which are used for binding a path with an Ethernet port.
lists the parameters that are used for binding a path.
Table 4-42
Parameters for bound path
Field
Value Range
Description
Configurable Ports
For example: VCTRUNKn
Displays all the available
VCTRUNK ports on the
board.
Available Resources
For example: VC4-1
Displays all the available
VC-4s.
Available Timeslots
For example: VC12-1
Displays all the available
timeslots.
VCTRUNK Port
VCTRUNKn
Displays the number (n) of
the VCTRUNK port.
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4 Configuring Ethernet Services
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4-139