58
4
3
Crimp the joint parts of the bare crimp terminal and
the conductor of the power cable using a crimping
tool.
Push the heat shrink tubing A towards the connector
until the heat shrink tubing covers the crimped parts
of the bare crimp terminal and the conductor of the
power cable. Then, heat the heat shrink tubing using
a heat gun.
The shapes of the crimped parts may vary according to the types of crimping dies.
Do not heat the heat shrink tubing for a long time to avoid damage to the insulation layer.
2
Assembling Cord End Terminals and Power Cables
Components of a cord end terminal and a power cable
Crimp pliers for the
cord end terminal
B
C
A
Utility knife