background image

Introduction to the OceanStor HVS85T&HVS88T

 

Overview 

This document guides you through a time-saving process for installing a storage system. For details about the 
installation, see the 

OceanStor HVS85T&HVS88T Storage System V100R001C00 Installation Guide

.  

Copyright ©Huawei Technologies Co., Ltd. 2014 
All rights reserved. 

As a new-generation storage system designed for large-scale enterprise data centers, HUAWEI OceanStor 
HVS85T&HVS88T features massive storage capacity, high-speed data access, high data availability, high 
storage utilization, environment protection, and ease of use.

 

OceanStor HVS85T&HVS88T  
Storage System V100R001C00  
Quick Installation Guide 

 
 
 

Issue: 03 
Release date: 2014-08-20 

Before You Start 

Where to get help 

Feedback 

You can register for a Huawei support account at this website to browse and download valuable information and 
sign up for product updates.  

Your feedback is important to us. If you have any comments about this document, please submit them to us on 

http://support.huawei.com/enterprise

.

 

Содержание OceanStor HVS85T

Страница 1: ...WEI OceanStor HVS85T HVS88T features massive storage capacity high speed data access high data availability high storage utilization environment protection and ease of use OceanStor HVS85T HVS88T Storage System V100R001C00 Quick Installation Guide Issue 03 Release date 2014 08 20 Before You Start Where to get help b Feedback c You can register for a Huawei support account at this website to browse...

Страница 2: ... eye protection Before you handle devices wear ESD clothes a pair of ESD gloves or an ESD wrist strap and remove conductive objects such as ornaments and watches Do not wear an ESD wrist strap during power on to avoid electric shocks To avoid data loss do not insert or remove hard disks controllers expansion modules or cables during power on To avoid device damage ensure that all devices are prope...

Страница 3: ...iers Adjustable wrench mini SAS cable Network cable 1a Ground cable The materials delivered to you vary depending on the disk configuration and the quantity of system bays specified in your order For information about the full list of required components see the Packing List AOC cable System bay 0 System bay 1 System bay 2 to 7 Disk bay Multi mode optical fiber cable ...

Страница 4: ...One engine System bays 0 and 1 up to sixteen 2 U disk enclosures with 2 5 inch disks or eight 4 U disk enclosures with 3 5 inch disks Other system bays up to seventeen 2 U disk enclosures with 2 5 inch disks or eight 4 U disk enclosures with 3 5 inch disks One 2 U SVP only for system bay 0 One 1 U KVM only for system bay 0 Two data switches only for system bay 1 Single disk bay 3 5 inch disks eigh...

Страница 5: ...Planning positions of holes on the floor only for underfloor cabling 5 2b Scenario 2 distributed layout Unit mm ...

Страница 6: ... side panel against the system bay before installation so that SAS cables can be routed between the two bays To remove a side panel do as follows 1 Insert the key locks on the front and rear doors and the side panels use the same key delivered with the bay to any of the two keyholes on the side panel and turn the key clockwise to open the lock and then do the same in the other keyhole 2 Pull the h...

Страница 7: ...between every two bays so that the front door of the bay on the right can move free when the front door of the bay on the left is fully open Use an adjustable wrench to extend the leveling caster until the caster are not touching the ground and the bay is level NOTICE ...

Страница 8: ...plates at the bay bottom near the rear door Connecting two bays needs six connecting plates two at the top two at the front and two at the back Use screws to fasten one end of a connecting plate to one of the adjacent bays and the other end to the other bay Then install the other connecting plates in the same way ...

Страница 9: ...system bays and disk bays Route cross bay network cables optical fiber cables and AOCs overhead as shown in the following figure Route the SAS cables between the adjacent system bay and disk bay as shown in the left figure You can also route them underfloor if there are holes for cables routing on the floor ...

Страница 10: ...10 4 Connecting Cables 10 Connecting cables for the SVP and the engine 4b ...

Страница 11: ... procedure because the cables between the SVP and engine are connected before delivery Otherwise you must connect the SVP to the two controllers of each engine in a daisy chain manner Connecting the SVP to the engines using network cables 4c 4 Connecting Cables ...

Страница 12: ... bay skip this procedure because there are no data switches Otherwise you must connect each of the two data switching modules of one engine to both data switches Connecting the data switches to the engines using AOCs 4d 4 Connecting Cables ...

Страница 13: ...13 13 Connecting SAS cables system bays and disk bays exist 4e 4 Connecting Cables ...

Страница 14: ...tion servers 4f Scenario 1 direct connection Scenario 2 connection through a switch Connect each engine to an application server through host ports 1 Gbit s iSCSI 10 Gbit s TOE 10 Gbit s FCoE or 8 Gbit s Fibre Channel 4 Connecting Cables ...

Страница 15: ...5 Connecting the SVP to a maintenance terminal 4g 4h All devices in a bay are connected to ground terminals on the bay before delivery Connect each bay to a ground bar in the equipment room using a ground cable 4 Connecting Cables ...

Страница 16: ...or is displaced Disk bay Check Item Normal Abnormal Optical fiber cable The cable is securely fastened in the ports The cable is loose or disconnected mini SAS cable Network cable AOC Power cable 5a 5b Take the PDU connector out from the accessories assemble the connector as shown in the following figures If the site is already available PDU socket please skip this step Connect the connector to an...

Страница 17: ... devices are correctly grounded before the storage system is connected to power source 6a Power On procedure Follow basic rules for the system power on sequence If the system includes disk bays they must be powered on before the system bays System bays must be powered on in ascending order from system bay 0 to system bay n In a scenario with multiple controllers all the controllers must be powered...

Страница 18: ...ller s power switch When the engine is powered on disk enclosures will start The process requires 5 15 minutes When the storage system is powering on the status indicator on the front door of system bay 0 is blinking green When the system is successfully powered on that indicator is steady green 6 Powering On the Storage System ...

Страница 19: ... storage system in SVP 5 Optional Import the license file Obtain the documentation for the host software from the delivery attached CD ROM Huawei customer service center Address Huawei Industrial Base Bantian Longgang Shenzhen 518129 People s Republic of China Website http support huawei com enterprise Local Huawei technical support personnel Obtain contact information for local Huawei offices at ...