![Huawei NetEngine5000E Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/huawei/netengine5000e/netengine5000e_configuration-manual_169429028.webp)
The system view is displayed.
Step 2
Run:
ntp-service refclock-master
[
ip-address
] [
stratum
]
An NTP primary clock is configured.
ip-address
specifies the IP address of the local reference clock. Reference clock addresses are
of the form 127.127.t.u. Here, "t" indicates the clock type and ranges from 0 to 37. Currently,
"t" is the local reference clock and the value is 1. "u" indicates the NTP process number, ranging
from 0 to 3. When no IP address is specified, the local clock whose IP address is 127.127.1.0
functions as the primary NTP clock by default.
stratum
specifies the stratum of the local reference clock. If this parameter is not specified, the
default stratum is 8.
Step 3
Run:
commit
The configurations are committed.
----End
2.3.2 Configuring the Unicast Server/Client Mode
This section describes how to configure the unicast server and client mode. In client/server mode,
the clock on the client synchronizes with the primary clock on the server.
Procedure
l
Configure the NTP client.
1.
Run:
system-view
The system view is displayed.
2.
(Optional) Run:
ntp-service source-interface
interface-type interface-number
[
vpn-
instance
vpn-instance-name
]
The specified source interface IP address is used as the source IP address to send NTP
packets irrespective of the out going interface.
3.
Run:
ntp-service unicast-server
ip-address
[
version
number
|
authentication-
keyid
key-id
|
source-interface
interface-type interface-number
|
vpn-
instance
vpn-instance-name
|
preference
]
*
The IP address of the NTP server is configured.
ip-address
is the IP address of the NTP server. It can be the IP address of the host
rather than a broadcast address, a multicast address, or the IP address of the reference
clock. If the source interface to send NTP packets is specified on the server, the IP
address of the server configured on the client should be the same; otherwise, the client
cannot process NTP packets sent from the server and clock synchronization fails.
Step 2 is optional. If
source-interface
is specified in both Step 2 and Step 3, use the
source interface specified in Step 3 preferentially.
HUAWEI NetEngine5000E Core Router
Configuration Guide - System Management
2 NTP Configuration
Issue 01 (2011-10-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
20