HUAWEI ME906s LTE M.2 Module
Hardware Guide
Electrical and Reliability Features
Issue 05 (2019-03-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
63
Item
Test Condition
Standard Sample
size
Results
Temperature
cycle
High temperature: 85ºC
Low temperature:
–40ºC
Temperature change
slope: 6ºC/min
Operation mode: no
power
Test duration: 168 h,
336 h, 500 h, 668 h for
inspection point
JESD22-
A104-C
50
pcs/group
Visual inspection: ok
Function test: ok
RF specification: ok
Cross section: ok
ESD
HBM (Human
Body Model)
1 kV (Class 1 B)
Operation mode: no
power
JESD22-
A114-D
3
pcs/group
Visual inspection: ok
Function test: ok
RF specification: ok
ESD with DVK
(or embedded in
the host)
Contact Voltage: ±2 kV,
±4 kV
Air Voltage : ±2 kV, ±4
kV, ±8 kV
Operation mode: working
with service connected
IEC6100
0-4-2
2 pcs
Visual inspection: ok
Function test: ok
RF specification: ok
Groups
≥ 2
5.6 EMC and ESD Features
The following are the EMC design comments:
Attention should be paid to static control in the manufacture, assembly,
packaging, handling, and storage process to reduce electrostatic damage to
HUAWEI module.
RSE (Radiated Spurious Emission) may exceed the limit defined by EN301489 if
the antenna port is protected by TVS (Transient Voltage Suppressor), which is
resolved by making some adjustments on RF match circuit.
TVS should be added on the USB port for ESD protection, and the parasitic
capacitance of TVS on D+/D- signal should be less than 2 pF. Common-mode
inductor should be added in parallel on D+/D- signal.
TVS should be added on the USIM interface for ESD protection. The parasitic
capacitance of TVS on USIM signal should be less than 10 pF.
Resistors in parallel and a 10 nF capacitor should be added on RESET# and
Power_On_Off signal to avoid shaking, and the distance between the capacitor
and the related pin should be less than 100 mil.
PCB routing should be V-type rather than T-type for TVS.
An integrated ground plane is necessary for EMC design.