Overview 

The LSBM1SRP main control board series is the switching route processing board of 

Quidway

®

 S8500. It can make configuration management and status monitor for entire 

system and has the clock processing function. The board provides data switch and route 

protocol processing function between Line Processing Unit (LPU) boards, implements the 

across-board forwarding of service data and implements the centralized switching of 

system. Each S8500 device should be configured with one main control board at least. 

Two main control boards are recommended for redundancy protection. At present, 

LSBM1SRP main control board provides five types: LSBM1SRP1N0, LSBM1SRP1N1, 

LSBM1SRP1N2, LSBM1SRP1N3 and LSBM1SRP1M0.   

As the core of S8500 route switch, LSBM1SRP switching route processing board provides 

the following functions:   

1.  Implement such functions as switching, route protocol processing, equipment 

management control and monitor, and clock processing.   

2.  Use 1+1 backup and 1:1 load sharing design, realize auto protection switchover and 

ensure the uninterrupted system running.   

3.  Monitor the environment and state, including the state of temperature, fan and power, 

and controls the rotation speed of each fan.   

4.  Provide a standard IDE interface, which can be inserted into CF card (Compact 

Flash Card) to provide data storage capability for system (the capacity of CF card is 
256 Mbytes by default, which can be expanded as required).   

5.  Back up the CF card and FAT table through NVRAM to save the configuration data of 

user.  

6.  Provide the running indicator for Line Processing Units (LPUs) for the front panel, 

which provides the running information of system vividly for user.   

7.  Provide multiple management interfaces such as 10/100M Ethernet port and RS232 

serial port, have an independent management channel for each LPU board and 
provide uniform management and maintenance for system.   

Содержание LSBM1SRP

Страница 1: ...LSBM1SRP switching route processing board provides the following functions 1 Implement such functions as switching route protocol processing equipment management control and monitor and clock processing 2 Use 1 1 backup and 1 1 load sharing design realize auto protection switchover and ensure the uninterrupted system running 3 Monitor the environment and state including the state of temperature fa...

Страница 2: ... interface can serve as a backup interface for the Console port to connect a background terminal or directly connect a Modem device for remote system debugging configuration maintenance and management It can also connect the background terminal computer Attributes Description Connector RJ 45 Standard Asynchronous EIA TIA 232 Service Connects a serial port of a PC through a Modem pair for a remote ...

Страница 3: ...t the remote network management workstation and implement system remote management Attributes Description Connector RJ 45 Number of ports one Rate 10 Mbps half duplex full duplex 100 Mbps half duplex full duplex Max transmission distance over the selected medium 100 m 328 ft over the category 5 twisted pair cable crossover cable is required Service System program upgrade and network management RS2...

Страница 4: ...input for internal clock modules or the clock benchmark for external devices Attributes Description Connector SMB 75JYWHD1 Number of ports Four Service Provides stratum 3 clock interface two interface used as input and two interface used as output The input port receives 2048 KHz or 2048 Kbps clock The output port provides 2048 KHz or 2048 Kbps clock externally The clock type is selected through D...

Страница 5: ...frame the main control board is in slots 7 and 8 Running Environment and Standard Environment Conditions Operation temperature 0 C 45 C Storage temperature 40 C 75 C Relative humidity 5 95 non condensing Fungus resistance level 0 Operation altitude 60 m 3000 m Security Standard Compliance EN 60950 1 LVD Directive UL 60950 1 Edition 1 April 1 2003 IEC 60950 1 EMC Standard Compliance CISPR 22 2003 0...