lists the checking items for other cable connections.
Table 4-7
Checklist for other cable connections
No.
Item
1
The connectors of the other cables must securely connected.
2
Labels on the cables are legible and bound based on the engineering requirements.
The cables must be bound tightly and neatly. The sheaths of the cables must not
be damaged.
3
Positions for routing the cables must meet requirements of the engineering design.
4.6 Power-on Check on an RHUB
This section describes the power-on check on the RHUB after the RHUB hardware is installed
and checked.
Context
DANGER
Power-on check involves high-voltage operation. Be cautious when conducting the power-on
check. Any direct contact with the input voltage or indirect contact through damp objects might
endanger your life.
Procedure
Step 1
Measure the RHUB earth resistance.
If...
Then...
The RHUB earth resistance is less than
10 ohms
Go to
.
The RHUB earth resistance is equal to or
larger than 10 ohms
Find out the cause and ensure that the resistance
meets requirement. Then, go to
Step 2
Measure the voltage of the RHUB.
If...
Then...
The external power supply ranges from
100 V AC to 240 V AC
Go to
.
The external power supply does not
range from 100 V AC to 240 V AC
Find out the cause and ensure that the resistance
meets requirement. Then, go to
LampSite
Installation Guide
4 Installing an RHUB