Figure 8-1
BIOS in the system
BIOS
OS
Process 2
Process 3
...
Process 1
For details, see the
HUAWEI Server Grantley Platform BIOS Parameter Reference
8.3 Management Module
The management module implements server management and complies with the Intelligent
Platform Management Interface 2.0 (IPMI 2.0) specifications. The management module is a
controller designed for power supply and fan management. As a supplement to the iBMC of
the server node, the management module monitors power supply and fan status, collects asset
information and real-time data, and performs fan speed adjustment and network convergence.
The management module provides the following functions:
l
Alarm management
The management module receives the alarms reported by the field replaceable units
(FRUs) and rectifies faults based on the alarm information.
l
Status monitoring
The management module monitors the operating status of FRUs in real time.
l
Device information management
The management module allows you to query information about device versions,
models, and asset information.
l
Heat dissipation control
The management module dynamically adjusts the fan speed based on the ambient
environment and workload.
l
IPMItool
The management module supports the commands from the IPMItool.
The management module supports RMCP, RMCP+, SSL, SSH, FTP, SFTP, and DHCP.
NOTE
For security purposes, FTP, RMCP, and RMCP+ are disabled by default.
For details, see the
FusionServer G5500 Server 1.0.0 HMM Command Reference
.
FusionServer G5500 Server
User Guide
8 Software and Configuration Utilities
Issue 02 (2017-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.