Figure 4-16
Installing the supercapacitor
Step 9
Install the cover.
Step 10
Install the compute node.
.
Step 11
Power on the compute node.
----End
4.3.11 Removing a Mezzanine Card
Procedure
Step 1
Record the mezzanine card configuration.
NOTE
l
When replacing an MZ220, MZ312, MZ520, MZ522, or MZ912 with a new one of the same model:
–
You do not need to record the mezzanine card configuration if stateless computing is enabled.
–
Record all the following configurations if stateless computing is not enabled.
l
When replacing a mezzanine card with another model, record all the following configurations.
l
BIOS configuration
For details, see the
of the mezzanine card you use.
l
OS configuration, including IP addresses, VLAN IDs, and NIC bonding configuration
–
The method used to query the IP address varies depending on the operating system:
n
If Windows is used, query the IP address in the NIC property window.
n
If VMware ESXi is used, press
Alt
+
F2
on the login page and query the IP
address.
n
If Linux is used, run the
ifconfig -a
command on the CLI.
–
To query the VLAN ID:
Refer to the
of the mezzanine card you use.
–
To query the NIC bonding configuration:
Refer to the
of the mezzanine card you use.
FusionServer Pro CH121 V5 Compute Node
Maintenance and Service Guide
4 Parts Replacement
Issue 06 (2019-08-10)
Copyright © Huawei Technologies Co., Ltd.
67