Condition
Result
Coding
protocol
Resolution
Frame rate
I-frame
interval
Minimum
required bit
rate
Supported
video storage
duration (h)
H.264
1080P
25
50
1M
66
H.265
720P
25
50
0.8M
75
H.264
720P
25
50
1M
66
H.265
720P
25
50
0.6M
105
H.264
720P
25
50
0.8M
75
----End
6.6.5.4 Setting Parameters on the VCN WebUI
Prerequisites
For details about the VCN hardware description and installation, see the "Hardware Guide" in
the corresponding VCN product documentation. For details about the VCN configuration, see
Configuration Guide.
The version number is subject to the
Quick Start
delivered with the VCN. The description and link in
this document are for reference only.
Context
A default IP address has been configured for the VCN before delivery. Modify the IP address
based on the actual network plan.
Procedure
Step 1
Modify the IP address for the VCN.
1.
Configure the PC IP address and the VCN IP address in the same network segment.
Enter the OMU Portal address (the default address for VCN is
https://192.168.1.100:8443; the default address for VCN540 is
https://192.168.2.101:8443) in the address bar of the Internet Explorer and press the
Enter
button.
The OMU Portal supports Internet Explorer 8.0 and later versions.
2.
On the login page, enter the user name
Admin
and preset password
Change_Me
, and
click
Log In
to enter the OMU Portal page.